The aerospace dual three-phase permanent magnet assisted synchronous reluctance starter-generator system’s power converter had an open-circuit fault diagnosis issue. To address this, a single-phase open-circuit fault diagnosis and localization method for power tubes based on the bus voltage and z1-z2 coordinate system current was proposed. Firstly, the starter-generator and power converter model were established by using the vector space decomposition method. Next, using this model, the single-phase double-tube open-circuit and single-phase single-tube open-circuit fault characteristics represented in the power converter’s DC bus voltage and z1-z2 coordinate system current trajectory were examined. A single-phase single-tube open circuit and single-phase double-tube open circuit fault diagnosis and location method based on z1-z2 coordinate system current and DC bus voltage was proposed to detect the occurrence of faults and determine the fault location. The experimental platform ultimately confirmed the method’s efficacy. The experimental findings show that the technique is capable of identifying and diagnosing power converter single-phase power tube open-circuit failures. This in turn provides important guidance for fault-tolerant operation after the fault occurs.
- Article type
- Year
In this paper, a suppression methodology based on the high voltage energy storage system and bidirectional energy conversion is proposed to solve the stability problem caused by the transient power demand of the radar/direct energy weapon and the bidirectional power flow of four-quadrant electric actuator. Firstly, a bidirectional energy control topology based on high-voltage battery and bidirectional power conversion is proposed, which uses the instantaneous charging and discharging of high-voltage battery to cut peaks and fill valleys to achieve bidirectional transient power control. Secondly, a comprehensive power supply management strategy based on bus voltage-load current and battery SOC is proposed to realize rapid detection of system load disturbance and fast configuration of power supply mode. Thirdly, a voltage stabilizing control method based on differential tracker and load current feedforward is proposed to improve the voltage performance of the converter under various loads. The simulation and experimental results show that the proposed method can effectively suppress the voltage fluctuation caused by high-power bidirectional transient load disturbance, and improve the robustness and quality of aerospace HVDC power supply system.
Open Access
Full Length Article
Issue
To improve the heat dissipation performance, this paper proposes a novel hybrid cooling method for high-speed high-power Permanent Magnet assisted Synchronous Reluctance Starter/Generator (PMaSynR S/G) in aerospace applications. The hybrid cooling structure with oil circulation in the housing, oil spray at winding ends and rotor end surface is firstly proposed for the PMaSynR S/G. Then the accurate loss calculation of the PMaSynR S/G is proposed, which includes air gap friction loss under oil spray cooling, copper loss, stator and rotor core loss, permanent magnet eddy current loss and bearing loss. The parameter sensitivity analysis of the hybrid cooling structure is proposed, while the equivalent thermal network model of the PMaSynR S/G is established considering the uneven spraying at the winding ends. Finally, the effectiveness of the proposed hybrid cooling method is demonstrated on a 40 kW/24000 r/min PMaSynR S/G experimental platform.
京公网安备11010802044758号