AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Open-circuit fault diagnosis of power tubes in power converter of dual three-phase starter-generator system

Huaji WANG1, Yu LIU2, Gaoyang SUN3, Dehong LI1, Jinquan XU2( )
China Helicopter Research and Development Institute,Jingdezhen 333001,China
School of Automation Science and Electrical Engineering,Beihang University,Beijing 100191,China
Suzhou Inovance United Power System Co.,Ltd.,Suzhou 215000,China
Show Author Information

Abstract

The aerospace dual three-phase permanent magnet assisted synchronous reluctance starter-generator system’s power converter had an open-circuit fault diagnosis issue. To address this, a single-phase open-circuit fault diagnosis and localization method for power tubes based on the bus voltage and z1-z2 coordinate system current was proposed. Firstly, the starter-generator and power converter model were established by using the vector space decomposition method. Next, using this model, the single-phase double-tube open-circuit and single-phase single-tube open-circuit fault characteristics represented in the power converter’s DC bus voltage and z1-z2 coordinate system current trajectory were examined. A single-phase single-tube open circuit and single-phase double-tube open circuit fault diagnosis and location method based on z1-z2 coordinate system current and DC bus voltage was proposed to detect the occurrence of faults and determine the fault location. The experimental platform ultimately confirmed the method’s efficacy. The experimental findings show that the technique is capable of identifying and diagnosing power converter single-phase power tube open-circuit failures. This in turn provides important guidance for fault-tolerant operation after the fault occurs.

CLC number: V242.2 Document code: A Article ID: 1001-5965(2025)09-2882-12

References

【1】
【1】
 
 
Journal of Beijing University of Aeronautics and Astronautics
Pages 2882-2893

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG H, LIU Y, SUN G, et al. Open-circuit fault diagnosis of power tubes in power converter of dual three-phase starter-generator system. Journal of Beijing University of Aeronautics and Astronautics, 2025, 51(9): 2882-2893. https://doi.org/10.13700/j.bh.1001-5965.2025.0425

730

Views

3

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 01 July 2025
Published: 16 July 2025
© Journal of Beijing University of Aeronautics and Astronautics