Discover the SciOpen Platform and Achieve Your Research Goals with Ease.
Search articles, authors, keywords, DOI, etc.
In this paper, a suppression methodology based on the high voltage energy storage system and bidirectional energy conversion is proposed to solve the stability problem caused by the transient power demand of the radar/direct energy weapon and the bidirectional power flow of four-quadrant electric actuator. Firstly, a bidirectional energy control topology based on high-voltage battery and bidirectional power conversion is proposed, which uses the instantaneous charging and discharging of high-voltage battery to cut peaks and fill valleys to achieve bidirectional transient power control. Secondly, a comprehensive power supply management strategy based on bus voltage-load current and battery SOC is proposed to realize rapid detection of system load disturbance and fast configuration of power supply mode. Thirdly, a voltage stabilizing control method based on differential tracker and load current feedforward is proposed to improve the voltage performance of the converter under various loads. The simulation and experimental results show that the proposed method can effectively suppress the voltage fluctuation caused by high-power bidirectional transient load disturbance, and improve the robustness and quality of aerospace HVDC power supply system.