During cardiovascular interventional surgeries, catheters come into mechanical contact with vascular tissues, resulting in friction, collisions, and compression that can damage the tissue. To address this, surface engineering is essential for modifying the catheter surface. Effective catheter coatings require high adhesion strength to prevent peeling or delamination from the inner surface, whereas the outer surface must provide excellent lubricity and biocompatibility. In this study, we used the layer-by-layer (LbL) technique to introduce catechol-modified chitosan (CC) and dopamine-modified oxidized hyaluronic acid (DOHA), which form a nanoscale, superhydrophilic, strongly adhesive, and biocompatible coating on cardiovascular catheters. Tight binding of CC and DOHA results from electrostatic interactions, chemical reactions, and catechol group enrichment, yielding an adhesion strength of up to 1 MPa. These CC/DOHA multilayers greatly enhance the lubrication performance of the TPU substrate, reducing the coefficient of friction (COF) by up to 95% compared with that of the uncoated state. After a 30-min friction test, the COF of the CC/DOHA16 coating only slightly increased from 0.032 to 0.044, demonstrating excellent stability. Evaluations revealed a reduction in vascular intima damage from grade 5 without coating to grade 3, confirming the effectiveness of the coating in minimizing friction-induced damage.
- Article type
- Year
- Co-author
Open Access
Research Article
Issue
Open Access
Research Article
Issue
Vascular interventional surgery is a minimally invasive treatment. This method involves introducing catheters, guidewires, and other precision instruments into the human body to locally diagnose and treat internal diseases. However, mechanical contact, such as friction, compression, and collision, inevitably occurs during the intervention process. This can cause tissue damage. Currently, mechanical damage to vascular tissues is evaluated primarily in qualitative terms, which limits accurate reflection of both the extent of tissue damage and its influencing factors. This paper specifically studies friction injury between interventional catheters and vascular tissues. This study develops the first quantification model of injury between catheters and blood vessels. The results revealed that increases in the normal force led to increased coefficients of friction (COF) and greater energy dissipation between the friction head and vascular tissue. In contrast, varying speeds produced a trend where the COF and energy dissipation first increased and then decreased. A quantitative evaluation system for vascular tissue injury was established on the basis of indicators such as endothelial cells, glycoproteins, curled tissues, and intimal thickness on the vascular surface. Using this system, damage scores and damage grades were assigned to surface injuries in friction experiments. Pearson correlation analysis revealed a strong correlation between the COF and injury score. The link between the normal load and sliding velocity was even greater than that between the friction time and injury score. These experimental results lay the foundation for quantitative mechanical damage evaluation. They enable the mapping of relationships between mechanical factors and tissue damage.
Open Access
Issue
Surface integrity has a critical impact on the functionality and performance of machined parts. Titanium alloys exhibit distinctive surface integrity characteristics and theoretical frameworks in cutting processes due to their unique crystalline structure and special physical and mechanical properties. Establishing a dedicated theoretical system for cutting-induced surface integrity tailored to titanium alloys holds substantial academic value and profound implications for engineering applications. In recent years, the deep integration of mechanical and materials sciences and advanced detection technologies has continuously driven innovative advancements in the theoretical understanding of surface integrity in titanium alloy cutting processes. Meanwhile, emerging technologies like 3D printing, energy-field-assisted cutting and clean cutting have also introduced new development opportunities for surface integrity investigations. However, systematic summaries of research achievements related to surface integrity in titanium alloy cutting remain insufficient, and a comprehensive framework is yet to be established. Therefore, this paper presents an independent and in-depth review of the latest advancements in the research on the surface integrity of titanium alloy cutting. First, the material characteristics of titanium alloys and advanced testing and characterisation methods are reviewed. Second, the deformation and microstructural evolution features and mechanisms of the machining-affected layer are analysed from various perspectives, including thermomechanical effects, dislocations, twinning, recrystallisation, phase transformations and texture evolution. The formation mechanisms and influencing factors of surface topographical characteristics are summarised. Subsequently, the mechanical characteristics, mechanisms and influencing factors of the machining-affected layer in terms of residual stresses and hardness are reviewed. Finally, the development of surface integrity theory under the influence of emerging technologies, such as additive manufacturing, clean cutting and energy-field-assisted cutting, is discussed. This review aims to provide theoretical support for constructing a cutting-induced surface integrity theory system tailored to titanium alloys and offers a valuable reference basis for optimising related manufacturing processes.
Open Access
Review Article
Issue
As the aging population increases, the global incidence of cardiovascular diseases is rapidly growing, and vascular intervention has become a mainstream treatment method for vascular diseases. However, due to the complexity of the in vivo environment, mechanical interactions such as compression, adhesion, and friction occur between the catheter and vascular tissue during the intervention process, which can cause varying degrees of tissue damage. This review examined the interaction mechanism between vascular tissue and interventional catheters in response to mechanical damage in interventional surgery. It also provided an overview of the work on surface modification of interventional catheters using hydrophilic lubricated and anti-adhesion coatings. The current paper aims to reduce postoperative complications for patients with cardiovascular disease and improve the safety and accuracy of cardiovascular surgery.
京公网安备11010802044758号