Successive Commutation Failure Mechanism Analysis and Prevention of Multi-infeed HVDC System Considering Reactive Power and Harmonic Interaction
CSEE Journal of Power and Energy Systems 2026, 12(5): 2425-2439
Published: 03 May 2024
Abstract PDF (2.1 MB) Collect
Downloads:0

This paper studies the successive commutation failure (SCF) mechanism considering the reactive power and harmonic interaction of a multi-infeed high voltage direct current (MIDC) system. It was found that the increase of reactive power exchanged on the tie line led to a decrease in the AC voltage amplitude of the healthy line during the SCF development stage. Hence, the probability of SCF increases due to the reactive power interaction. Besides, the voltage distortion components in AC voltage of healthy lines caused by harmonic interaction play a negative role in the commutation process, which may lead to SCF. Also, there is a nonlinear coupling between the effects of reactive power and harmonics on SCF. Thus, the reactive power impact index (RPII) and the voltage distortion index (VDI) are proposed to assess the degree of reactive power impact and voltage distortion of the DC line, respectively. Furthermore, the SCF prevention strategy of the MIDC system is proposed, which is realized by reducing the advance angle of the faulty line based on RPII and triggering the healthy line earlier based on VDI. Finally, the simulation models of the MIDC CIGRE benchmark system and Henan multi-infeed UHVDC system are built, and the effectiveness of the proposed SCF prevention strategy is verified under different fault types.

Open Access Regular Paper Issue
Commutation Failure Fault Level Calculation Method Under Three-phase-to-ground Faults Considering Multi-factor Influence
CSEE Journal of Power and Energy Systems 2026, 12(5): 2480-2488
Published: 17 November 2023
Abstract PDF (1.6 MB) Collect
Downloads:0

Earlier works have reported some critical commutating voltage or commutation failure immunity index calculation methods for commutation failure (CF) mitigation capability evaluation of line-commutated-converter-based high-voltage direct-current. However, accuracy of earlier methods is limited since they only consider commutating voltage drop and DC current rise. Hence, a commutation failure fault level calculation method under three-phase-to-ground faults considering multi-factor influence is proposed in this paper. First, transient time-domain response of DC current after fault is gained and DC current harmonics are calculated by Fast Fourier Transform. Then, AC current harmonics are estimated based on the coupling relationship of DC current and AC current of the inverter. Furthermore, supply voltage-time area and zero-crossing considering the harmonic voltage are estimated. Then, dynamic interaction between AC and DC system caused by constant extinction angle controller is considered by the power flow equation. Finally, discrete commutation processes are constructed based on commutation voltage-time area rule to determine occurrence of CF under different fault levels. Calculation results of the tradition method and the proposed method are compared with simulation results based on PSCAD/EMTDC.

Total 2