Publications
Sort:
Open Access Original Article Issue
Comparing Virtual Reality Headsets With Standard Diagnostic Workstations for MRI Grading of Knee Meniscus Lesions: A Pilot Study
iRADIOLOGY 2026, 4(5): 412-423
Published: 20 October 2026
Abstract PDF (3.1 MB) Collect
Downloads:0
Background

Virtual reality (VR) is becoming increasingly popular in radiology, with a variety of diagnostic applications being tested. However, VR is yet to be tested in the context of MRI studies. This study evaluated the agreement between a VR headset and a standard radiology workstation in grading meniscus lesions on knee MRI.

Methods

Fifty‐two knee MRIs were reviewed by a consultant musculoskeletal radiologist and a radiology resident. Each interpreted the examinations on a diagnostic screen and then re‐evaluated them using a VR headset. Meniscus lesions were graded using Lotysch's five‐segment classification. Agreement was assessed using Cohen's kappa and descriptive statistics, with significance at p < 0.05.

Results

Cohen's kappa was not always calculable due to asymmetry in data. The consultant showed moderate‐to‐near‐perfect agreement between VR and standard screens, 76% for the medial and 87% for the lateral meniscus. The resident showed moderate to minor agreement, 64% for the medial and 70% for the lateral meniscus. Agreement for nonpathological segments was high: 94% (consultant) and 76% (resident). Agreement dropped for pathological segments, particularly type 2b superior lesions (29% consultant and 0% resident).

Conclusions

VR headsets demonstrate strong comparability for excluding meniscal lesions and moderate accuracy in grading pathology, although agreement for pathological segments was limited. Although not a replacement for diagnostic screens, they may be useful in select cases. As technology advances, VR could support remote interpretation and supplement traditional radiology workflows.

Open Access Original Article Issue
A Pilot Study on the Accuracy of Large Language Models (ChatGPT, Google Bard, and Microsoft Copilot) for Selecting the Correct Modality for Musculoskeletal Clinical Cases According to the ACR's Appropriateness Criteria
iRADIOLOGY 2026, 4(1): 35-39
Published: 28 December 2025
Abstract PDF (798.2 KB) Collect
Downloads:51
Background

Large language models (LLMs) are becoming more commonly used in many aspects of radiology. Some authors have previously tested the capacity of various LLMs to suggest the correct imaging modality according to the guidelines of various associations, such as the American College of Radiology. This study aims to test whether free LLMs can suggest the most appropriate imaging modality in various musculoskeletal radiological cases.

Methods

We tested ChatGPT 3.5, Google Bard, and Copilot (Precise) to see if they could correctly suggest the appropriate imaging modality per the American College of Radiology's Appropriateness Criteria, using clinical vignettes from the musculoskeletal section. Seventy‐six vignettes were submitted to each chatbot, with the answer only being considered correct if it was the most appropriate according to the guidelines.

Results

ChatGPT 3.5 was correct in 82% of cases, Bard in 66%, and Copilot in 89% of cases. Bard was unable to answer in four cases, claiming that as a LLM, it was not capable of answering the question.

Conclusions

We found that all three LLMs were able to suggest the correct modality in a majority of cases. However, there was variability in the performance of the LLMs, with Copilot performing the best overall, with an accuracy of 89%.

Total 2