AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home iRADIOLOGY Article
PDF (3.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Article | Open Access

Comparing Virtual Reality Headsets With Standard Diagnostic Workstations for MRI Grading of Knee Meniscus Lesions: A Pilot Study

Thomas Saliba1,2 ( ), Sanjiva Pather3
Radiology Department, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium
Radiology Department, Hôpital de Braine L'Alleud, Braine L'Alleud, Belgium
Show Author Information

Abstract

Background

Virtual reality (VR) is becoming increasingly popular in radiology, with a variety of diagnostic applications being tested. However, VR is yet to be tested in the context of MRI studies. This study evaluated the agreement between a VR headset and a standard radiology workstation in grading meniscus lesions on knee MRI.

Methods

Fifty‐two knee MRIs were reviewed by a consultant musculoskeletal radiologist and a radiology resident. Each interpreted the examinations on a diagnostic screen and then re‐evaluated them using a VR headset. Meniscus lesions were graded using Lotysch's five‐segment classification. Agreement was assessed using Cohen's kappa and descriptive statistics, with significance at p < 0.05.

Results

Cohen's kappa was not always calculable due to asymmetry in data. The consultant showed moderate‐to‐near‐perfect agreement between VR and standard screens, 76% for the medial and 87% for the lateral meniscus. The resident showed moderate to minor agreement, 64% for the medial and 70% for the lateral meniscus. Agreement for nonpathological segments was high: 94% (consultant) and 76% (resident). Agreement dropped for pathological segments, particularly type 2b superior lesions (29% consultant and 0% resident).

Conclusions

VR headsets demonstrate strong comparability for excluding meniscal lesions and moderate accuracy in grading pathology, although agreement for pathological segments was limited. Although not a replacement for diagnostic screens, they may be useful in select cases. As technology advances, VR could support remote interpretation and supplement traditional radiology workflows.

Graphical Abstract

References

【1】
【1】
 
 
iRADIOLOGY
Pages 412-423

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Saliba T, Pather S. Comparing Virtual Reality Headsets With Standard Diagnostic Workstations for MRI Grading of Knee Meniscus Lesions: A Pilot Study. iRADIOLOGY, 2026, 4(5): 412-423. https://doi.org/10.1002/ird3.70099

5

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 10 July 2025
Revised: 24 April 2026
Accepted: 09 August 2026
Published: 20 October 2026
© 2026 The Author(s). Tsinghua University Press.

This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.