A novel paramagnetic ions-mediated magnetic relaxation switching biosensor was developed to detect hypoxanthine and histamine for the evaluation of fish freshness and quality. With the catalysis of xanthine oxidase or diamine oxidase, hypoxanthine and histamine can be decomposed to generate hydrogen peroxide. Hydrogen peroxide can act as a reductant or oxidant to induce the conversion of paramagnetic ions of different valence (Mn (Ⅷ)/Mn (Ⅱ) and Fe (Ⅱ)/Fe (Ⅲ)), leading to an obvious change in magnetic signals. Herein, paramagnetic ions and hydrogen peroxide were employed to fabricate a magnetic signal readout system for the quantitative analysis of hypoxanthine and histamine. As a result, this biosensor allowed highly sensitive detection of hypoxanthine and histamine. The linear ranges for hypoxanthine and histamine were 0.525-1050 and 5-1000 µmol/L, the limits of detection were 0.17 and 2.34 µmol/L, respectively. The results of this biosensor for crucian carp samples were in good agreement with those of high performance liquid chromatography (HPLC). The proposed biosensor is sensitive, rapid, low cost and promising for fish freshness detection and quality control.
- Article type
- Year
- Co-author
Open Access
Issue
Open Access
Issue
In this study, a magnetic relaxation immunosensor based on gold core@platinum shell (Au@Pt) nanozyme-mediated paramagnetic ion valence transition was constructed and used for the rapid detection of Salmonella in foods. Pt@Au nanozyme with high stability and good catalytic performance was synthesized by a microwave-assisted hydrothermal (MAH) method, and its catalase-like activity was used to catalyze hydrogen peroxide (H2O2). The remaining H2O2 could convert MnO4- into Mn2+ through a redox reaction. The significant difference in magnetic signals between MnO4- and Mn2+ allowed the quantitative analysis of hydrogen peroxide. In the immunoreaction, the concentration of Salmonella was directly proportional to the content of “detection antibody-Pt@Au”. Au@Pt could regulate the H2O2-mediated MnO4-/Mn2+ conversion system and consequently control the change of magnetic signal, ultimately allowing the quantitative analysis of Salmonella. The detection limit of this method for Salmonella was 50 CFU/mL, and the linear range was 1×102–5×107 CFU/mL. The results of this method for Salmonella in eggs were in good agreement with those of fluorescence quantitative polymerase chain reaction (PCR). This method has the advantages of high sensitivity, good stability, simple operation and low cost, thus having a good application prospect in the rapid detection of foodborne pathogens.
京公网安备11010802044758号