AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (4.4 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Paramagnetic Ions-mediated Magnetic Relaxation Switching Biosensor for Fish Freshness Analysis

Ziyue CAO1 , Yongzhen DONG1, Xuewen PENG1, Rui CHEN1, Feng JIANG2, Zhiyong FAN2, Xiaoping YU3, Yiping CHEN1 ( )
College of Food Science and Technology, Huazhong Agricultural University, Wuhan 430070, China
Hubei Provincial Institute for Food Supervision and Test, Wuhan 430074, China
College of Life Sciences, China Jiliang University, Hangzhou 310018, China
Show Author Information

Abstract

A novel paramagnetic ions-mediated magnetic relaxation switching biosensor was developed to detect hypoxanthine and histamine for the evaluation of fish freshness and quality. With the catalysis of xanthine oxidase or diamine oxidase, hypoxanthine and histamine can be decomposed to generate hydrogen peroxide. Hydrogen peroxide can act as a reductant or oxidant to induce the conversion of paramagnetic ions of different valence (Mn (Ⅷ)/Mn (Ⅱ) and Fe (Ⅱ)/Fe (Ⅲ)), leading to an obvious change in magnetic signals. Herein, paramagnetic ions and hydrogen peroxide were employed to fabricate a magnetic signal readout system for the quantitative analysis of hypoxanthine and histamine. As a result, this biosensor allowed highly sensitive detection of hypoxanthine and histamine. The linear ranges for hypoxanthine and histamine were 0.525-1050 and 5-1000 µmol/L, the limits of detection were 0.17 and 2.34 µmol/L, respectively. The results of this biosensor for crucian carp samples were in good agreement with those of high performance liquid chromatography (HPLC). The proposed biosensor is sensitive, rapid, low cost and promising for fish freshness detection and quality control.

CLC number: TS201.6;TS207.3;TS207.7 Document code: A Article ID: 1002-6630(2022)20-0304-09

References

【1】
【1】
 
 
Food Science
Pages 304-312

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
CAO Z, DONG Y, PENG X, et al. Paramagnetic Ions-mediated Magnetic Relaxation Switching Biosensor for Fish Freshness Analysis. Food Science, 2022, 43(20): 304-312. https://doi.org/10.7506/spkx1002-6630-20211130-369

450

Views

2

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 30 November 2021
Published: 25 October 2022
© Beijing Academy of Food Sciences 2022.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).