Publications
Sort:
Issue
Selection of Reconstruction Parameters for Sound Insulation Measurement Based on Near-Field Acoustic Holography
Journal of South China University of Technology (Natural Science Edition) 2022, 50(5): 109-117
Published: 25 May 2022
Abstract PDF (5.4 MB) Collect
Downloads:1

Near-field acoustic holography has wide application prospects in the field measurement related to sound insulation of prefabricated buildings and components. In order to reduce the complexity of holographic measurement and improve the accuracy of sound field reconstruction, this study firstly used point sound source as an example to explore the variation law of sound insulation measurement accuracy with parameters by means of numerical simulation and experimental verification. Then it discussed the optimization range of parameters. Finally, this study veri-fied the effectiveness of the reconstruction parameters selected in this paper about sound insulation measurement. The results show that the simulation values are basically consistent with the experimental values. That is, the accuracy decreases with the increase of reconstruction distance and sampling spacing, while increases with the increase of holographic aperture. In addition, to best improve accuracy, the values of reconstruction distance and sampling spacing should not exceed the half-wavelength corresponding to the highest frequency, and the aperture of the holographic plane should be 1.5 times of the component size. By optimizing the reconstruction parameters, it can not only reduce the complexity of sound insulation measurement, but also improve the measurement accuracy, as well as obtain better sound insulation measurement accuracy, improving the engineering practicability of the near-field acoustic holographic sound insulation measurement technology.

Issue
Influence of Near-Field Acoustic Holography Reconstruction Parameters on the Accuracy of Sound Insulation Measurement
Journal of South China University of Technology (Natural Science Edition) 2024, 52(11): 1-8
Published: 25 November 2024
Abstract PDF (2.1 MB) Collect
Downloads:4

Equivalent source method near-field acoustic holography can be applied in sound insulation measurement of the building components. When near-field acoustic holography is used to measure the sound insulation volume of components, the reconstruction parameters significantly affect the acoustic field reconstruction results. Based on the theoretical analysis of near-field holographic acoustic insulation measurement by equivalent source method, the compound sound pressure signal of the surface of the component was measured by the microphone array, and the sound insulation volume and surface normal sound intensity distribution of the component were obtained through the acoustic field reconstruction. To further investigate the influence of reconstruction parameters on the accuracy of equivalent source method near-field acoustic holography, experiments on sound insulation measurement of building components were carried out in the sound insulation room by the control variable method in comparison with the traditional sound pressure method. The results show that when the position of the equivalent source surface changes from −2 cm to −5 cm, the average error value of the reconstruction of the surface normal sound intensity increases from 3.9 dB to 5.6 dB, and the average error value of the reconstruction of the sound insulation volume increases from 5.2 dB to 6.9 dB, and the measurement error increases with the distance of the equivalent source surface, so it is suitable for the equivalent surface to be close to the sound source surface. When the holographic measurement surface distance is 4, 8, and 16 cm, the average error values of the reconstruction of the surface normal sound intensity are 0.6, 1.9, and 5.5 dB, and the average error values of the reconstruction of the sound insulation volume are 0.9, 1.4, and 4.6 dB, respectively. The measurement errors increase with the holographic measurement surface distance, so it is recommended to keep the holographic measurement surface distance within 8 cm. When the number of equivalent source points is consistent with the number of measuring points on the holographic surface, the difference with the traditional sound pressure method is only 0.84 dB. When the number of equivalent source points is inconsistent with the number of measuring points on the holographic surface, the average error values of the reconstruction of the sound insulation volume and surface normal sound intensity distribution increase to 4.6~6.8 dB. By optimizing the reconstruction parameters, the accuracy of component sound insulation measurement can be effectively improved. It has important reference significance for laboratory measurement of sound insulation performance and methods of building components and has high reference value in the practical application of sound insulation measurement technology.

Total 2