AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Influence of Near-Field Acoustic Holography Reconstruction Parameters on the Accuracy of Sound Insulation Measurement

Hongwei WANG1,2, Guangyao ZHANG1, Tao SHEN3( ), Shujie LI1, Chenxi YANG1, Yang ZHANG1
School of Architecture, South China University of Technology, Guangzhou 510640, Guangdong, China
State Key Laboratory of Subtropical Building and Urban Science, South China University of Technology, Guangzhou 510640, Guangdong, China
Infrastructure Department, South China University of Technology, Guangzhou 510640, Guangdong, China
Show Author Information

Abstract

Equivalent source method near-field acoustic holography can be applied in sound insulation measurement of the building components. When near-field acoustic holography is used to measure the sound insulation volume of components, the reconstruction parameters significantly affect the acoustic field reconstruction results. Based on the theoretical analysis of near-field holographic acoustic insulation measurement by equivalent source method, the compound sound pressure signal of the surface of the component was measured by the microphone array, and the sound insulation volume and surface normal sound intensity distribution of the component were obtained through the acoustic field reconstruction. To further investigate the influence of reconstruction parameters on the accuracy of equivalent source method near-field acoustic holography, experiments on sound insulation measurement of building components were carried out in the sound insulation room by the control variable method in comparison with the traditional sound pressure method. The results show that when the position of the equivalent source surface changes from −2 cm to −5 cm, the average error value of the reconstruction of the surface normal sound intensity increases from 3.9 dB to 5.6 dB, and the average error value of the reconstruction of the sound insulation volume increases from 5.2 dB to 6.9 dB, and the measurement error increases with the distance of the equivalent source surface, so it is suitable for the equivalent surface to be close to the sound source surface. When the holographic measurement surface distance is 4, 8, and 16 cm, the average error values of the reconstruction of the surface normal sound intensity are 0.6, 1.9, and 5.5 dB, and the average error values of the reconstruction of the sound insulation volume are 0.9, 1.4, and 4.6 dB, respectively. The measurement errors increase with the holographic measurement surface distance, so it is recommended to keep the holographic measurement surface distance within 8 cm. When the number of equivalent source points is consistent with the number of measuring points on the holographic surface, the difference with the traditional sound pressure method is only 0.84 dB. When the number of equivalent source points is inconsistent with the number of measuring points on the holographic surface, the average error values of the reconstruction of the sound insulation volume and surface normal sound intensity distribution increase to 4.6~6.8 dB. By optimizing the reconstruction parameters, the accuracy of component sound insulation measurement can be effectively improved. It has important reference significance for laboratory measurement of sound insulation performance and methods of building components and has high reference value in the practical application of sound insulation measurement technology.

CLC number: TU112.2 Article ID: 1000-565X(2024)11-0001-08

References

【1】
【1】
 
 
Journal of South China University of Technology (Natural Science Edition)
Pages 1-8

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG H, ZHANG G, SHEN T, et al. Influence of Near-Field Acoustic Holography Reconstruction Parameters on the Accuracy of Sound Insulation Measurement. Journal of South China University of Technology (Natural Science Edition), 2024, 52(11): 1-8. https://doi.org/10.12141/j.issn.1000-565X.240029

853

Views

4

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 16 January 2024
Published: 25 November 2024
© Journal of South China University of Technology(Natural Science Edition)