Publications
Sort:
Issue
Skin friction measurement technique in rarefied regime and drag force reduction test
Acta Aeronautica et Astronautica Sinica 2025, 46(12)
Published: 16 October 2024
Abstract PDF (11.9 MB) Collect
Downloads:9

This paper develops a skin friction measurement technique based on skin friction balance for rarefied flow applications, and applies the technique to improve surface smoothness and reduce drag. A comparative measurement experiment is conducted in a hypersonic low-density wind tunnel, involving flat plate models and skin friction balances with smooth and conventional wall surfaces. The flat plate models are arranged symmetrically with smooth and conventional wall surfaces, each paired with skin friction balances having induction surfaces corresponding to the wall surface type. The balance structure is designed based on the cantilever beam principle, considering overload protection and thermal insulation. Micro-friction loading is achieved through load increment method to calibrate the balance closest to the experimental conditions. Through quantitative evaluation and active control, the error in wind tunnel tests introduced by surface pressure can be controlled within 1% and the error introduced by the offset installation of the balance floating head can be controlled within 2%. Seven repetitive tests at the Mach number of 22 show that the measurement standard deviation of skin friction balance is less than 2.9%; the smooth wall surface is more effective in reducing drag compared to the conventional wall surface, with an average drag reduction rate of 25.1%.

Open Access Research Article Issue
Balance calibration method based on modern design of experiments
Acta Aerodynamica Sinica 2024, 42(3): 111-118
Published: 04 September 2023
Abstract PDF (1.6 MB) Collect
Downloads:24

The accuracy of aerodynamic force measurement in the wind tunnel test is dominated by the wind tunnel balance calibration. To improve the quality and efficiency of balance calibration, this work takes the BCS-100 calibration system as the research object, and proposes a calibration method for the wind tunnel balance calibration using modern design of experiments (MDOE). Aiming at the problem that the systemic error is coupled with the response in traditional calibration using one factor at a time (OFAT), the randomization, repetition and blocking strategies based on MDOE are used to control the calibration systemic error. The central composited design (CCD) based on response surface methodology is chosen to generate the calibration matrix, which is composed of 86 sample points in total, including 64 fractional factor points, 12 axial factor points and 10 central factor points. The actual loading sequence of all the points is randomized, and the loading is completed in a short time as a single sample block, with the central factor points satisfying the repetition strategy. Finally, a contrastive calibration of OFAT and MDOE is applied in the calibration system. The normal probability distribution of the fitting load residuals for horizontal and lateral components shows that the sample points in MDOE have better independence, and the residuals can be reduced by 84% at most. The testing loads shows that both MDOE and OFAT have a similar comprehensive repetition error for all components, but the comprehensive loading error using MDOE can achieve an improvement up to 54% for the horizontal and lateral components. The present study indicates that MDOE can reduce the calibration systematic error effectively and has a better prediction capacity for small horizontal and lateral components.

Total 2