AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Publishing Language: Chinese | Open Access

Balance calibration method based on modern design of experiments

Chunfeng LIU( ), Ruiting WANG, Xuefeng WANG, Xiaotian HE, Tingting ZHANG
China Academy of Aerospace Aerodynamics, Beijing 100074, China
Show Author Information

Abstract

The accuracy of aerodynamic force measurement in the wind tunnel test is dominated by the wind tunnel balance calibration. To improve the quality and efficiency of balance calibration, this work takes the BCS-100 calibration system as the research object, and proposes a calibration method for the wind tunnel balance calibration using modern design of experiments (MDOE). Aiming at the problem that the systemic error is coupled with the response in traditional calibration using one factor at a time (OFAT), the randomization, repetition and blocking strategies based on MDOE are used to control the calibration systemic error. The central composited design (CCD) based on response surface methodology is chosen to generate the calibration matrix, which is composed of 86 sample points in total, including 64 fractional factor points, 12 axial factor points and 10 central factor points. The actual loading sequence of all the points is randomized, and the loading is completed in a short time as a single sample block, with the central factor points satisfying the repetition strategy. Finally, a contrastive calibration of OFAT and MDOE is applied in the calibration system. The normal probability distribution of the fitting load residuals for horizontal and lateral components shows that the sample points in MDOE have better independence, and the residuals can be reduced by 84% at most. The testing loads shows that both MDOE and OFAT have a similar comprehensive repetition error for all components, but the comprehensive loading error using MDOE can achieve an improvement up to 54% for the horizontal and lateral components. The present study indicates that MDOE can reduce the calibration systematic error effectively and has a better prediction capacity for small horizontal and lateral components.

CLC number: V411.3 Document code: A

References

【1】
【1】
 
 
Acta Aerodynamica Sinica
Pages 111-118

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LIU C, WANG R, WANG X, et al. Balance calibration method based on modern design of experiments. Acta Aerodynamica Sinica, 2024, 42(3): 111-118. https://doi.org/10.7638/kqdlxxb-2023.0107

671

Views

24

Downloads

0

Crossref

4

Scopus

2

CSCD

Received: 26 June 2023
Revised: 13 August 2023
Published: 04 September 2023
© The journal of Acta Aerodynamica Sinica.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).