Comprehensive energy systems can synergize multiple forms of energy to meet user-side load demand, making full use of renewable energy for energy supply. However, the system often suffers from high instability in renewable energy supply or high variability in demand during operation, resulting in a mismatch between system supply and demand. This mismatch directly affects the energy supply efficiency of the system. The traditional single optimization approach, e.g., the two-stage co-optimization approach, has limitations in achieving both economic and energy savings, particularly as it does not consider the time scale. To address these issues, this study proposes a design framework for a two-layer collaborative optimization approach that incorporates multiple time scales and demand response coordination. The upper layer optimizes the capacity of the energy storage system, while the lower layer optimizes the coordinated operation of the energy supply facilities. In the lower layer optimization, the day-ahead scheduling phase considers tariff-based demand response to shift and curtail hot and cold electricity loads. The intraday optimization stage adjusts the results of the day-ahead scheduling to further optimize energy distribution and utilization, enhancing system economics and environmental friendliness. Analyzed in conjunction with practical cases, the results demonstrate that the optimization method improves the operational stability of the system and can reduce the total annual operating cost by 7.61%. Increasing the use of hybrid energy storage in the integrated energy system reduces total annual operating costs by 4.01%. If the use of demand response is added to the integrated energy system, the total annual operating cost can be reduced by 5.38%. This paper provides a theoretical reference for integrated energy system operation optimization studies.
- Article type
- Year
- Co-author
Phase change material (PCM) is outstanding for building thermal insulation, competent for indoor cooling enhancement. However, single-PCM deployment seems not good enough for better cooling performance and higher energy efficiency. Therefore, experiment with mathematic optimization over PCM ceiling-floor cascaded cooling system has been conducted. An experimental test rig has been built with different PCMs attached to the room ceiling/floor respectively. In this manuscript, optimized system configuration for summer cooling has been obtained via control variable method based on the experimental weather data in Tianjin, China. The optimal systematic configuration has been determined as 4-cm-thick PCM panels both for floor/roof, and 23/28 ℃ in phase change temperature arrangement in floor/roof sequence, along with heat transfer fluid (HTF) of 19 ℃ circulating through the capillaries inserted at middle location of the PCM panels in Down-feed/Up-return manner with the interval of 15 cm, is recommended. Cooling HTF being 3 ℃ higher than the experimental results after optimization, indicates a decent energy conservation potential. Also, thermal conductivity is suggested to be 3.45 W/(m·K), and possessing around 200 J/g in latent thermal energy storage ability. Finally, it is concluded that differentiated phase change temperature arrangement in increasing manner along the heat transfer fluid circulation direction brings about better cooling performance.
Walking-induced fluctuations have a significant influence on indoor airflow and pollutant dispersion. This study developed a method to quantify the robustness of ventilation systems in the control of walking-induced fluctuation control. Experiments were conducted in a full-scale chamber with four different kinds of ventilation systems: ceiling supply and side return (CS), ceiling supply and ceiling return (CC), side supply and ceiling return (SC), and side supply and side return (SS). The measured temperature, flow and pollutant field data was (1) denoised by FFT filtering or wavelet transform; (2) fitted by a Gaussian function; (3) feature-extracted for the range and time scale disturbance; and then (4) used to calculate the range scale and time scale robustness for different ventilation systems with dimensionless equations developed in this study. The selection processes for FFT filtering and wavelet transform, FFT filter cut-off frequency, wavelet function, and decomposition layers are also discussed, as well as the threshold for wavelet denoising, which can be adjusted accordingly if the walking frequency or sampling frequency differs from that in other studies. The results show that for the flow and pollutant fields, the use of a ventilation system can increase the range scale robustness by 19.7%–39.4% and 10.0%–38.8%, respectively; and the SS system was 7.0%–25.7% more robust than the other three ventilation systems. However, all four kinds of ventilation systems had a very limited effect in controlling the time scale disturbance.
The couple of radiation with convection heating owned advantages of less energy utilization, healthier and more comfortable indoor environment. However, local thermal discomfort was often induced by large vertical temperature difference and radiation asymmetry temperature. This work studied indoor thermal environment characteristics under different coupling ways of radiation and convection heating terminals through experiments and CFD simulation. The studied five scenarios were denoted as: (Ⅰ) lateral air supply + adjacent side wall radiation, (Ⅱ) lateral air supply + opposite side wall radiation, (Ⅲ) lateral air supply + floor radiation, (Ⅳ) lateral air supply + adjacent side wall radiation + floor radiation, and (Ⅴ) lateral air supply + opposite side wall radiation + floor radiation. The overall thermal comfort indices (including air diffusion performance index (ADPI), predicted mean vote (PMV), and predicted percent of dissatisfaction (PPD)) and local thermal comfort indices under different scenarios were investigated. For Scenarios Ⅰ–Ⅲ, the local dissatisfaction rates caused by vertical air temperature difference were 0.4%, 0.1%, and 0.2%, respectively, which belonged to "A" class according to the ISO-7730 Standard. While the vertical asymmetric radiation temperature of Scenario Ⅰ/Ⅱ was about 6.5 ℃ lower than that of Scenario Ⅲ/Ⅳ/Ⅴ. The ADPI for Scenarios Ⅲ–Ⅴ were about respectively 5.7%, 16.7%, and 21.0% higher than that of Scenarios Ⅰ–Ⅱ, indicating that a large radiation area and radiation angle coefficient could reduce the discomfort caused by radiant temperature asymmetry. The coupling mode improved local discomfort by decreasing vertical temperature difference and radiation asymmetry temperature wherefore improving the PMV from -1.6 to -1. The lateral air supply coupled with asymmetric radiation heating could potentially improve the thermal comfort of occupied area, while the comprehensive effect of thermal environmental improvement, energy-saving, and cost-effectiveness needes to be further investigated.
京公网安备11010802044758号