Research Article

Thermal environment investigation of asymmetric radiation coupled with convection heating

Man Fan1,2,3, Jia Wang1, Lanlan Zhang1, Han Li1, Xiangfei Kong1( ), Chenxiao Zheng4
School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin 300401, China
State Key Laboratory of Building Safety and Built Environment, Beijing 100013, China
National Engineering Research Center of Building Technology, Beijing 100013, China
School of Mechanical Engineering, Tianjin University of Commerce, Tianjin 300134, China
Show Author Information

Abstract

The couple of radiation with convection heating owned advantages of less energy utilization, healthier and more comfortable indoor environment. However, local thermal discomfort was often induced by large vertical temperature difference and radiation asymmetry temperature. This work studied indoor thermal environment characteristics under different coupling ways of radiation and convection heating terminals through experiments and CFD simulation. The studied five scenarios were denoted as: (Ⅰ) lateral air supply + adjacent side wall radiation, (Ⅱ) lateral air supply + opposite side wall radiation, (Ⅲ) lateral air supply + floor radiation, (Ⅳ) lateral air supply + adjacent side wall radiation + floor radiation, and (Ⅴ) lateral air supply + opposite side wall radiation + floor radiation. The overall thermal comfort indices (including air diffusion performance index (ADPI), predicted mean vote (PMV), and predicted percent of dissatisfaction (PPD)) and local thermal comfort indices under different scenarios were investigated. For Scenarios Ⅰ–Ⅲ, the local dissatisfaction rates caused by vertical air temperature difference were 0.4%, 0.1%, and 0.2%, respectively, which belonged to "A" class according to the ISO-7730 Standard. While the vertical asymmetric radiation temperature of Scenario Ⅰ/Ⅱ was about 6.5 ℃ lower than that of Scenario Ⅲ/Ⅳ/Ⅴ. The ADPI for Scenarios Ⅲ–Ⅴ were about respectively 5.7%, 16.7%, and 21.0% higher than that of Scenarios Ⅰ–Ⅱ, indicating that a large radiation area and radiation angle coefficient could reduce the discomfort caused by radiant temperature asymmetry. The coupling mode improved local discomfort by decreasing vertical temperature difference and radiation asymmetry temperature wherefore improving the PMV from -1.6 to -1. The lateral air supply coupled with asymmetric radiation heating could potentially improve the thermal comfort of occupied area, while the comprehensive effect of thermal environmental improvement, energy-saving, and cost-effectiveness needes to be further investigated.

References

【1】
【1】
 
 
Building Simulation
Pages 1309-1321

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Fan M, Wang J, Zhang L, et al. Thermal environment investigation of asymmetric radiation coupled with convection heating. Building Simulation, 2022, 15(7): 1309-1321. https://doi.org/10.1007/s12273-021-0856-x

1593

Views

21

Crossref

23

Web of Science

20

Scopus

3

CSCD

Received: 15 July 2021
Revised: 27 September 2021
Accepted: 18 October 2021
Published: 25 November 2021
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2021