Research Article Issue
Analysis of the factors influencing the airflow behavior in an impinging jet ventilation room
Building Simulation 2021, 14(3): 749-762
Published: 21 September 2020
Abstract PDF (575.3 KB) Collect
Downloads:102

A validated CFD model is employed to predict the airflow behavior in an impinging jet ventilation (IJV) room with cool, isothermal or warm jets. By using the numerical results, the influences of jet discharge height, supply grille shape and room height on the jet flow behavior as well as the draught discomfort are analyzed for IJV operating in heating scenarios. The results indicate that the warm supply jet of IJV rises upward to the ceiling after spreading along the floor for a certain distance due to thermal buoyancy, resulting in a limited dispersion area, while the cool and isothermal jets of IJV always spread along the whole floor. When IJV is used for space heating, the lower the jet discharge height, the farther the supply air spreads along the floor, and the supply grille shape and room height almost have no effect on the air dispersion area. The results also show that the energy-efficient advantage of IJV in its heating mode compared to the mixing ventilation (MV) system is more remarkable in higher rooms. Moreover, there is a risk of draught discomfort in IJV heating rooms and it is recommended to wear socks to avoid this discomfort.

Research Article Issue
Theoretical predictions of transient natural displacement ventilation
Building Simulation 2013, 6(2): 165-171
Published: 02 February 2013
Abstract PDF (988.2 KB) Collect
Downloads:63

The transient natural displacement ventilation driven by a localized heat source at the floor of a room is examined to understand the airflow behavior and the relevant thermal stratification characteristic. Two modified theoretical models are developed on the basis of classical plume theory and Kaye and Hunt’s model. The buoyant layer is modeled as composed of a near-ceiling layer and a warm layer rather than being well-mixed. Some assumptions on the buoyancies of the near-ceiling layer and the outflow through the upper opening are made in the two modified models for simplicity. Comparisons are made between the predictions of Kaye and Hunt’s model and the two modified models and experimental data reported in the literature. Two modified models are shown to perform better than Kaye and Hunt’s model. Meanwhile, the predictions of the modified model I seem to agree slightly better with the experimental data than those of the modified model II. Typically, the average relative deviation between the three models’ predictions of the lowest interface height and the experimental data are about 4.2% (modified model I), 4.6% (modified model II), and 4.9% (Kaye and Hunt’s model).

Research Article Issue
Transient pollutant flushing of buoyancy-driven natural ventilation
Building Simulation 2012, 5(2): 147-155
Published: 09 May 2012
Abstract PDF (1.1 MB) Collect
Downloads:98

The transient flushing of neutrally-buoyant pollutants from a naturally ventilated enclosure is investigated. A simplified transient model for buoyancy-driven natural ventilation produced by a point source of heat is presented to describe the ventilation development from the plume generation to its steady state. The instantaneous thermal stratification interface height and ventilation flow rate and the time taken for the flow to reach the steady state are then examined by the transient model. The results indicate that the decrease of the thermal stratification interface height with dimensionless time, the steady-state interface height and the dimensionless time taken for the flow to reach the steady state are only determined by the dimensionless effective area of the vents. The ventilation flow rate can be increased by decreasing the enclosure floor area or increasing the effective vent area, enclosure height or source buoyancy flux. Accordingly, for rooms with smaller floor area, larger effective vent area or larger source buoyancy flux, ventilation airflow provides more effective flushing of neutrally-buoyant pollutant. Nevertheless, increasing the enclosure height is only beneficial to flush the pollutant from the lower layer rapidly and is disadvantageous to reduce the pollutant concentration of the upper layer.