AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Transient pollutant flushing of buoyancy-driven natural ventilation

Xiufeng Yang1,2, Guangxiang Wang3, Ke Zhong1( ), Yanming Kang1
School of Environmental Science and Engineering, Donghua University, Shanghai 201620,China
School of Energy and Power Engineering, Yangzhou University, Jiangsu 225127, China
Jiangsu Yang-an Group Co.,Ltd, Jiangsu 225000, China
Show Author Information

Abstract

The transient flushing of neutrally-buoyant pollutants from a naturally ventilated enclosure is investigated. A simplified transient model for buoyancy-driven natural ventilation produced by a point source of heat is presented to describe the ventilation development from the plume generation to its steady state. The instantaneous thermal stratification interface height and ventilation flow rate and the time taken for the flow to reach the steady state are then examined by the transient model. The results indicate that the decrease of the thermal stratification interface height with dimensionless time, the steady-state interface height and the dimensionless time taken for the flow to reach the steady state are only determined by the dimensionless effective area of the vents. The ventilation flow rate can be increased by decreasing the enclosure floor area or increasing the effective vent area, enclosure height or source buoyancy flux. Accordingly, for rooms with smaller floor area, larger effective vent area or larger source buoyancy flux, ventilation airflow provides more effective flushing of neutrally-buoyant pollutant. Nevertheless, increasing the enclosure height is only beneficial to flush the pollutant from the lower layer rapidly and is disadvantageous to reduce the pollutant concentration of the upper layer.

References

【1】
【1】
 
 
Building Simulation
Pages 147-155

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yang X, Wang G, Zhong K, et al. Transient pollutant flushing of buoyancy-driven natural ventilation. Building Simulation, 2012, 5(2): 147-155. https://doi.org/10.1007/s12273-012-0077-4

1107

Views

12

Crossref

N/A

Web of Science

11

Scopus

0

CSCD

Received: 23 November 2011
Revised: 29 February 2012
Accepted: 05 March 2012
Published: 09 May 2012
© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2012