Research Article | Open Access

Energy performance analysis of multi-chiller cooling systems for data centers concerning progressive loading throughout the lifecycle under typical climates

Yingbo Zhang1Hangxin Li1( )Shengwei Wang1,2( )
Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
Research Institute for Smart Energy, The Hong Kong Polytechnic University, Hong Kong, China
Show Author Information

Abstract

The increasing demand for cooling energy in data centers has become a global concern. Existing studies lack a comprehensive analysis of the energy performance of widely used multi-chiller cooling systems in air-cooled data centers throughout their lifecycle,especially concerning progressive loading. To bridge this gap,this study conducts a thorough assessment of the energy performance of multi-chiller cooling systems throughout the entire lifecycle. Additionally,the impact of climate conditions on the energy efficiency of the cooling systems is analyzed,considering design variations for typical climates. Multi-chiller cooling system models are developed using the test data of cooling equipment and typical control algorithms. The energy performance of the cooling system is thoroughly analyzed under full-range cooling loads and climate conditions. Results show that free cooling time could differ up to 1442 hours at different part load ratios in the same location. Furthermore,the cooling system’s coefficient of performance (COP) varies significantly,by up to 6,at different part load ratios,corresponding to a difference in power usage effectiveness (PUE) up to 0.14. Notably,the average cooling system COP throughout the lifecycle loading is found to be only 11.7,2.9 lower than the design system COP.

References

【1】
【1】
 
 
Building Simulation
Pages 1693-1708

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhang Y, Li H, Wang S. Energy performance analysis of multi-chiller cooling systems for data centers concerning progressive loading throughout the lifecycle under typical climates. Building Simulation, 2024, 17(10): 1693-1708. https://doi.org/10.1007/s12273-024-1167-9

1468

Views

117

Downloads

10

Crossref

9

Web of Science

9

Scopus

0

CSCD

Received: 25 April 2024
Revised: 10 July 2024
Accepted: 17 July 2024
Published: 29 August 2024
© Author(s) 2024

This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/