AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

CFD modeling of dynamic airflow and particle transmission in an aircraft lavatory

Pin Li1, Wei Liu3, Tengfei (Tim) Zhang1,2( )
Tianjin Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China
School of Civil Engineering, Dalian University of Technology, Dalian, China
Division of Sustainable Buildings, Department of Civil and Architectural Engineering, KTH Royal Institute of Technology, Brinellvägen 23, Stockholm, 100 44, Sweden
Show Author Information

Abstract

Lavatories are frequently used facilities, especially on long-haul flights. Flushing a vacuum toilet in a lavatory can induce strong airflow, produce aerosols in the toilet bowl, and resuspend deposited particles from the floor. However, the exact particle transport routes and the fates of particle after toilet flushing are unclear so far. This investigation used computational fluid dynamics (CFD) to model the transient airflow and pollutant transport after a toilet flushing process in a lavatory of a commercial aircraft. The time-varying pressure profile measured in a laboratory was assigned to the drainage valve as boundary conditions. The aerosols generated inside the toilet bowl during flushing and the particles resuspended from the lavatory floor were used as particle sources. Lagrangian tracking of airborne particles in the lavatory was conducted. In addition, ammonia gas was used to examine odor perception. The multi-physics software program COMSOL 5.4 was employed for numerical solution after being validated. The results revealed that more than 70% of the generated particles in the toilet bowl are drained into sewage. A few particles may leak out of the toilet bowl and remain suspended in the air for more than five minutes when the toilet lid is open during flushing. Flushing the toilet with a closed lid can effectively reduce the particle leakage and the spread of odor gas, but it leads to greater deposition of particles on both the lid and seat. There is a slight inhalation exposure risk in the initial three minutes after flushing with a closed lid.

Electronic Supplementary Material

Download File(s)
bs-16-8-1375_ESM.pdf (295.6 KB)

References

【1】
【1】
 
 
Building Simulation
Pages 1375-1390

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li P, Liu W, Zhang T(. CFD modeling of dynamic airflow and particle transmission in an aircraft lavatory. Building Simulation, 2023, 16(8): 1375-1390. https://doi.org/10.1007/s12273-023-1031-3

1589

Views

22

Crossref

17

Web of Science

19

Scopus

3

CSCD

Received: 06 December 2022
Revised: 02 April 2023
Accepted: 11 April 2023
Published: 14 July 2023
© Tsinghua University Press 2023