Lavatories are frequently used facilities, especially on long-haul flights. Flushing a vacuum toilet in a lavatory can induce strong airflow, produce aerosols in the toilet bowl, and resuspend deposited particles from the floor. However, the exact particle transport routes and the fates of particle after toilet flushing are unclear so far. This investigation used computational fluid dynamics (CFD) to model the transient airflow and pollutant transport after a toilet flushing process in a lavatory of a commercial aircraft. The time-varying pressure profile measured in a laboratory was assigned to the drainage valve as boundary conditions. The aerosols generated inside the toilet bowl during flushing and the particles resuspended from the lavatory floor were used as particle sources. Lagrangian tracking of airborne particles in the lavatory was conducted. In addition, ammonia gas was used to examine odor perception. The multi-physics software program COMSOL 5.4 was employed for numerical solution after being validated. The results revealed that more than 70% of the generated particles in the toilet bowl are drained into sewage. A few particles may leak out of the toilet bowl and remain suspended in the air for more than five minutes when the toilet lid is open during flushing. Flushing the toilet with a closed lid can effectively reduce the particle leakage and the spread of odor gas, but it leads to greater deposition of particles on both the lid and seat. There is a slight inhalation exposure risk in the initial three minutes after flushing with a closed lid.
- Article type
- Year
A machining workshop requires ventilation that removes oil mist particles efficiently and conditions air to a comfortable temperature. Displacement ventilation has been reported to be highly efficient in removing airborne pollutants in a workshop. However, the traditional wall-mounted displacement ventilation system may be inadequate for delivering conditioned, clean air to the internal zone of a large-span workshop. This investigation proposed an improved wall-mounted displacement ventilation system in which machining equipment is elevated, relay fans are operated in corridors in the cooling season, and ceiling air exhausts are lowered. The proposed ventilation system was compared with the traditional wall-mounted displacement ventilation system and a displacement ventilation system with multiple local diffusers in the corridors, separately. A validated computational fluid dynamics (CFD) software program was used to investigate the three ventilation systems in both the cooling and heating seasons. The airflow, oil mist particle concentration, and air temperature under the three ventilation systems were evaluated. The results revealed that the traditional wall-mounted displacement ventilation system is inappropriate for use in a large-span workshop, particularly in the cooling season. The proposed improved wall-mounted displacement ventilation provided the lowest oil mist particle concentration in the breathing zone and an appropriate air temperature in the occupied zone in both the cooling and heating seasons. Notably in the cooling season, the proposed system reduced the oil mist particle concentration by 48.5% in the breathing zone as compared with the traditional system. Such an improved ventilation system is highly recommended for use in large-span workshops.
京公网安备11010802044758号