AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Applicability of high-temperature cooling systems in different European countries from the view of the condensation risk

Vladimír Zmrhal( ), Martin Barták
Czech Technical University in Prague, Faculty of Mechanical Engineering, Department of Environmental Engineering Technicka 4, 160 00 Prague 6, Czech Republic
Show Author Information

Abstract

Due to the different approaches in determining the ventilation airflow rate per person for workspaces, where high-temperature air conditioning systems are used for air conditioning, problems with the condensation of water vapour on the cold surfaces of the system can occur. The article analyses the risk of condensation in various European cities using the available climatic data. Systems with cooling ceilings and cooling beams with a ventilation device operating in parallel are taken into account. Different ventilation airflow rates per person were analysed. On the example of a room equipped with high-temperature cooling, an energy simulation calculation is performed, which includes a ventilation and air-conditioning system with the possibility of capacity control. It is clear from the results that the condensation of water vapour can be prevented by technical measures at the cost of reducing the cooling capacity, which can affect the achievement of the thermal comfort of those present. In the end, suitable solutions are discussed, which should already be adopted at the time the device is designed so that the risk of condensation is not a major obstacle in the operation of these energy-efficient systems. An irreplaceable role in the operation of high-temperature cooling systems is played by a measurement and control system with a suitable algorithm to prevent condensation.

References

【1】
【1】
 
 
Building Simulation
Pages 1453-1466

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zmrhal V, Barták M. Applicability of high-temperature cooling systems in different European countries from the view of the condensation risk. Building Simulation, 2021, 14(5): 1453-1466. https://doi.org/10.1007/s12273-020-0753-8

1674

Views

9

Crossref

7

Web of Science

9

Scopus

0

CSCD

Received: 01 July 2020
Accepted: 01 December 2020
Published: 20 January 2021
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2021