Insufficient fresh air supply due to the increased air tightness of building envelopes after building renovations and window upgrades is a major concern of HVAC engineering today. The paper demonstrates the application of CFD simulations in the development of a compact decentralised ventilation unit with integrated heat recovery system for local ventilation of rooms, targeting this common issue. The device houses an innovative cyclically rotating recuperative heat exchanger, allowing effective condensate removal and de-icing in winter for its independent operation throughout the year. The paper introduces the ventilation unit, describes preparation of its numerical models, and conducts CFD simulation using Ansys Fluent software. The initial design of the device was improved following the findings of the numerical analysis, and the proposed adjustments were tested through follow-up CFD simulations, confirming that the desired outcomes were achieved. A separate CFD analysis was performed to assess the use of different air supply elements at the air outlet to the room, recommending the use of adjustable nozzles. A prototype ventilation unit was manufactured and the volume flow rate under different operating conditions was measured to be compared with the simulation results. The outcome of the research is a new type of compact local ventilation unit. An increase in device energy efficiency was achieved, with the aid of simulations, while maintaining its compact size. In addition to presenting the potential of using variant CFD analysis in the development of new HVAC equipment, the paper also indicates the drawbacks of using the Multiple Reference Frame (MRF) method to approximate the rotation of radial fan impellers in CFD simulations.
- Article type
- Year
Due to the different approaches in determining the ventilation airflow rate per person for workspaces, where high-temperature air conditioning systems are used for air conditioning, problems with the condensation of water vapour on the cold surfaces of the system can occur. The article analyses the risk of condensation in various European cities using the available climatic data. Systems with cooling ceilings and cooling beams with a ventilation device operating in parallel are taken into account. Different ventilation airflow rates per person were analysed. On the example of a room equipped with high-temperature cooling, an energy simulation calculation is performed, which includes a ventilation and air-conditioning system with the possibility of capacity control. It is clear from the results that the condensation of water vapour can be prevented by technical measures at the cost of reducing the cooling capacity, which can affect the achievement of the thermal comfort of those present. In the end, suitable solutions are discussed, which should already be adopted at the time the device is designed so that the risk of condensation is not a major obstacle in the operation of these energy-efficient systems. An irreplaceable role in the operation of high-temperature cooling systems is played by a measurement and control system with a suitable algorithm to prevent condensation.
京公网安备11010802044758号