Abstract

Demand-controlled ventilation (DCV) is commonly implemented to provide variable amounts of outdoor air according to an internal ventilation demand. The objective of the present study is to investigate the applicability and the performance of occupancy-based DCV schemes in comparison with time-based and CO2-based DCV schemes. To do this, we apply the occupancy estimation method by the Bayes theorem to control the ventilation rate of an office building in real-time. We investigated six cases in total (two cases for each control scheme). Experiments were conducted in a small office room with controllable ventilation equipment and relevant sensors. The observed results indicated that the occupancy-based schemes relying on Bayes theorem could be applied successfully to perform continuous control of ventilation rates without causing recursive problems. Additionally, we discussed the time delays associated with the control procedure, including dispersion time, sensor-response time, and data processing time. Finally, we compared the performance of the proposed approach in six DCV cases in terms of a resultant indoor CO2 level and the total ventilation-air volume. We concluded that DCV control based on both occupancy and floor area provided the best conformity to the ASHRAE standard among the analyzed schemes.

References

【1】
【1】
 
 
Building Simulation
Pages 1487-1497

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Rahman H, Han H. Real-time ventilation control based on a Bayesian estimation of occupancy. Building Simulation, 2021, 14(5): 1487-1497. https://doi.org/10.1007/s12273-020-0746-7

895

Views

12

Crossref

14

Web of Science

16

Scopus

0

CSCD

Accepted: 12 November 2020
Published: 09 January 2021
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2021