Publications
Sort:
Research Article Issue
Real-time ventilation control based on a Bayesian estimation of occupancy
Building Simulation 2021, 14(5): 1487-1497
Published: 09 January 2021
Abstract PDF (2.4 MB) Collect
Downloads:72

Demand-controlled ventilation (DCV) is commonly implemented to provide variable amounts of outdoor air according to an internal ventilation demand. The objective of the present study is to investigate the applicability and the performance of occupancy-based DCV schemes in comparison with time-based and CO2-based DCV schemes. To do this, we apply the occupancy estimation method by the Bayes theorem to control the ventilation rate of an office building in real-time. We investigated six cases in total (two cases for each control scheme). Experiments were conducted in a small office room with controllable ventilation equipment and relevant sensors. The observed results indicated that the occupancy-based schemes relying on Bayes theorem could be applied successfully to perform continuous control of ventilation rates without causing recursive problems. Additionally, we discussed the time delays associated with the control procedure, including dispersion time, sensor-response time, and data processing time. Finally, we compared the performance of the proposed approach in six DCV cases in terms of a resultant indoor CO2 level and the total ventilation-air volume. We concluded that DCV control based on both occupancy and floor area provided the best conformity to the ASHRAE standard among the analyzed schemes.

Research Article Issue
Bayesian estimation of occupancy distribution in a multi-room office building based on CO2 concentrations
Building Simulation 2018, 11(3): 575-583
Published: 03 October 2017
Abstract PDF (5.7 MB) Collect
Downloads:94

Occupancy information in an office building is an important asset for determining energy-efficient operations and emergency evacuation of a building. In this study, we developed a method to estimate the occupancy distribution in a multi-room office building using Bayesian inference. The Markov chain Monte Carlo algorithm was used to estimate the real-time occupancy in individual rooms based on indoor carbon dioxide concentrations. The office building was made-up of five rooms with different physical configurations and dimensions, and the rooms were air-conditioned and ventilated by a central air handling unit. The carbon dioxide concentration data were generated by the simulation software CONTAMW according to a given schedule of occupancy and the supply airflow rates in each room. The objective of the present paper is to investigate the effects of various parameters of Bayesian inference on the accuracy of estimation results. The parameters include the probability of prior information, the uncertainty level of CO2 data, and the time interval for monitoring CO2.

Total 2