Analysis of the factors influencing the airflow behavior in an impinging jet ventilation room

Xiufeng Yang2, Xiao Ye1,3, Bin Zuo2, Ke Zhong1( ), Yanming Kang1( )
School of Environmental Science and Engineering, Donghua University, Shanghai, 201620, China
School of Hydraulic, Energy and Power Engineering, Yangzhou University, Yangzhou, 225127, China
School of Mechanical and Automobile Engineering, Shanghai University of Engineering Science, Shanghai 201620, China
Show Author Information

Abstract

A validated CFD model is employed to predict the airflow behavior in an impinging jet ventilation (IJV) room with cool, isothermal or warm jets. By using the numerical results, the influences of jet discharge height, supply grille shape and room height on the jet flow behavior as well as the draught discomfort are analyzed for IJV operating in heating scenarios. The results indicate that the warm supply jet of IJV rises upward to the ceiling after spreading along the floor for a certain distance due to thermal buoyancy, resulting in a limited dispersion area, while the cool and isothermal jets of IJV always spread along the whole floor. When IJV is used for space heating, the lower the jet discharge height, the farther the supply air spreads along the floor, and the supply grille shape and room height almost have no effect on the air dispersion area. The results also show that the energy-efficient advantage of IJV in its heating mode compared to the mixing ventilation (MV) system is more remarkable in higher rooms. Moreover, there is a risk of draught discomfort in IJV heating rooms and it is recommended to wear socks to avoid this discomfort.

References

【1】
【1】
 
 
Building Simulation
Pages 749-762

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yang X, Ye X, Zuo B, et al. Analysis of the factors influencing the airflow behavior in an impinging jet ventilation room. Building Simulation, 2021, 14(3): 749-762. https://doi.org/10.1007/s12273-020-0690-6

1519

Views

42

Crossref

N/A

Web of Science

48

Scopus

0

CSCD

Received: 01 July 2019
Accepted: 16 July 2020
Published: 21 September 2020
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020