Research Article

A novel circulated air curtain system to confine the transmission of exhaled contaminants: A numerical and experimental investigation

Haixin Wang1, Hua Qian1( ), Rong Zhou2,3( ), Xiaohong Zheng1,4
School of Energy and Environment, Southeast University, Nanjing 210096, China
First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510000, China
Guangzhou Angel Biosafety Co., Ltd, Guangzhou 510000, China
Jiangsu Provincial Key Laboratory of Solar Energy Science and Technology, School of Energy and Environment, Southeast University, Nanjing 210096, China
Show Author Information

Abstract

Air curtain is an efficient device for cutting off airflow and confining contaminants. Inspired by the ability, a circulated air curtain composed of end-to-end plane jets generated by a relay of air pillars is proposed to confine exhaled contaminants in this study. Furthermore, the optimization study of computational fluid dynamics (CFD) is conducted to explore cutting-off performance and find better design parameters under different conditions, i.e., human-curtain distance, enclosure shape, jet velocity from air pillar, and exhalation modes. The multidirectional blockage and vortex-like rotative transmission routes of exhaled airflow are observed when air curtain exists. Results indicate that contaminants are concentrated around the source. The average mole fraction of exhaled contaminants outside air curtain under different human-curtain distance decreases 4.3%-19.6% compared to mixing ventilation with same flux. Shortening the human-curtain distance can improve the performance of air curtain and may change the direction of exhaled airflow. Moreover, It has better performance when the enclosure shape is close to a circle. Higher jet velocity is better for improving the confinement performance, but the trend is not very obvious as velocity increases. For exhalation modes, it is more challenging to control exhaled contaminants for intense exhalation activity (such as coughing) in steady simulation, but results in transient simulation show better performance when coughing only once. These results can provide a reference for the subsequent design and improvement in applying air curtain in hospital wards or other places, especially during the period of flu outbreak.

Electronic Supplementary Material

Video
12273_0667_ESM.mp4

References

【1】
【1】
 
 
Building Simulation
Pages 1425-1437

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang H, Qian H, Zhou R, et al. A novel circulated air curtain system to confine the transmission of exhaled contaminants: A numerical and experimental investigation. Building Simulation, 2020, 13(6): 1425-1437. https://doi.org/10.1007/s12273-020-0667-5

1556

Views

36

Crossref

N/A

Web of Science

42

Scopus

7

CSCD

Received: 01 November 2019
Accepted: 25 May 2020
Published: 04 August 2020
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020