AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Using air curtains to reduce short-range infection risk in consulting ward: A numerical investigation

Jin Ye1,2, Hua Qian1,2( ), Jianchao Ma1,2, Rong Zhou3,4, Xiaohong Zheng1,2,5
School of Energy and Environment, Southeast University, Nanjing 210096, China
Engineering Research Center of BEEE, Ministry of Education of China, Nanjing 210096, China
First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510000, China
Guangzhou Angel Biosafety Co., Ltd, Guangzhou 510000, China
Jiangsu Provincial Key Laboratory of Solar Energy Science and Technology, Nanjing, 210096, China
Show Author Information

Abstract

Air curtains is promising in reducing the short-range infection risk in hospitals. To quantitatively evaluate its performance, this paper explores air curtains equipped on normal consulting desk to avoid doctor’s direct exposure to the patient exhaled pollutants. A numerical investigation is conducted to evaluate the effects of supply air velocity and angle on cutting off performance. Simulation results show that the average mass fraction of exhaled pollutants decreases significantly (70%-90%) in the consulting ward, indicating satisfying performance of air curtains. Increasing supply air velocity is demonstrated to be conducive in forming full air curtains, whereas an excessively high supply air velocity may be of adverse effects by entraining exhaled flow. Besides, the supply air angle is also critical due to its coupling with supply air velocity. It is found that larger angle (0°-40°) is better where velocity is less than 3 m/s, otherwise a small angle (20°) is preferable where velocity is larger than 3 m/s. Exhaled flow could be well suppressed at the supply air angle 20° but moves over air curtains at 40°. This study can provide effective and intuitive guidance in applying air curtains in consulting wards.

Electronic Supplementary Material

Video
12273_2020_649_MOESM1_ESM.avi
12273_2020_649_MOESM2_ESM.avi
12273_2020_649_MOESM3_ESM.avi

References

【1】
【1】
 
 
Building Simulation
Pages 325-335

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ye J, Qian H, Ma J, et al. Using air curtains to reduce short-range infection risk in consulting ward: A numerical investigation. Building Simulation, 2021, 14(2): 325-335. https://doi.org/10.1007/s12273-020-0649-7

1159

Views

41

Crossref

N/A

Web of Science

41

Scopus

5

CSCD

Received: 22 December 2019
Accepted: 09 April 2020
Published: 26 June 2020
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020