Small-signal Stability Criterion of the PMSG-based Wind Farm via the VSC‒HVDC System in the Timescale of DC Voltage Dynamics
Advanced Engineering Sciences 2026, 58(6): 171-182
Published: 27 September 2024
Abstract PDF (1.8 MB) Collect
Downloads:0
Objective

Offshore wind power development increasingly relies on voltage source converter-based high-voltage direct current (VSC‒HVDC) transmission to accommodate large power capacities over long distances. However, dynamic interactions between wind turbine generators and VSC‒HVDC systems can induce oscillations, as demonstrated by incidents such as the 2014 resonance accident in the German North Sea and similar oscillation events in Chinese wind power projects. In this study, we aimed to address small-signal stability (SSS) issues in these systems by deriving analytical criteria to characterize the interactions between permanent magnet synchronous generators (PMSG) and VSC‒HVDC systems and provide a simpler approach to SSS assessment.

Methods

The SSS of the PMSG-based wind farm connected to the VSC‒HVDC system was evaluated using an SSS criterion. At the direct current (DC) voltage dynamic timescale, the PMSG model retained the low-frequency phase-locked loop (PLL) and the DC voltage control outer loop of the grid-side converter, whereas the VSC‒HVDC model retained its alternate current (AC) voltage control outer loop. All PMSGs in the PMSG-based wind farm subsystem were assumed to exhibit identical dynamic characteristics. Based on this assumption, reduced-order models of the PMSG-based wind farm subsystem and the VSC‒HVDC subsystem were derived. Then, a reduced-order model of the entire system was developed. The coefficients of the characteristic equation of the reduced-order model were expressed in terms of the line connection reactance and PMSG output active power. The Routh-Hurwitz stability criterion was then applied to derive the SSS criteria associated with the line connection reactance and PMSG output active power. These criteria simplified the SSS assessment process by explaining why increased PMSG output power or weaker grid connections increased the risk of instability. The SSS criteria were established as follows: 1) Criterion 1: At a fixed line connection reactance xL, the system’s SSS depended on the maximum allowable active power output tP0 of the PMSG. Higher PMSG output power increased the risk of instability. 2) Criterion 2: At a fixed PMSG output active power Pg0, the system’s SSS depended on the maximum allowable line reactance tL0. Greater line reactance increased the likelihood of instability. tL0 and tP0 were determined as the smallest positive real roots that satisfied all inequalities of the Routh-Hurwitz stability criterion for the reduced-order model. We identified three primary factors that contributed to small-signal instability in a PMSG-based wind farm connected to the VSC‒HVDC system: 1) PMSG output active power, 2) line connection reactance, and 3) control parameters of the PMSG and VSC‒HVDC. The high order of the PMSG dynamic model increased the complexity of the full-order system model and presented challenges for theoretical analysis. Simulation and numerical results confirmed the validity of the proposed criteria.

Results and Discussions

The validity of the derived SSS criteria was evaluated through two case studies. Case 1: The criteria were verified for a single PMSG connected to the VSC‒HVDC system under two scenarios. Scenario 1.1: At a fixed-line connection reactance of xL = 0.50 p.u., the influence of PMSG output active power on the system’s SSS was investigated. The maximum PMSG output active power that satisfied the SSS criterion was calculated as tP0 = 0.58. For verification, the PMSG output active power was gradually increased from 0.50 to 0.60 p.u., and the dominant oscillation modes were calculated using the full-order and reduced-order models. At Pg0 = 0.58, the eigenvalues of the full-order and reduced-order models were 0.120 ± j31.180 and 0.023 ± j31.170, respectively. The results demonstrated that the system became unstable when Pg0 > 0.58 p.u. Scenario 1.2: At a fixed PMSG output active power of Pg0 = 0.65 p.u., the influence of line connection reactance on SSS was examined. The maximum line connection reactance that satisfied the SSS criterion was calculated as tL0 = 0.47. For verification, the line connection reactance was increased from 0.40 to 0.50 p.u., and the dominant oscillation modes were calculated using both models. At xL = 0.47, the eigenvalues of the full-order and reduced-order models were 0.14 ± j31.21 and 0.035 ± j31.34, respectively. The results indicated that the system became unstable when xL > 0.47. Case 2: The criteria were validated for a wind farm comprising 15 PMSGs connected to the VSC‒HVDC system under two scenarios. Scenario 2.1: At a fixed line connection reactance of xL = 0.12 p.u., the effect of PMSG output active power on the system’s SSS was investigated. The maximum output power that satisfied the SSS criterion was calculated as tP0 = 0.155. For verification, the PMSG output active power was increased from 0.150 to 0.157 p.u., and the dominant oscillation modes were calculated. At Pg0 = 0.157, the eigenvalues of the full-order and reduced-order models were 0.160 ± j36.690 and 0.049 ± j36.870, respectively. The results demonstrated that the system became unstable when Pg0 > 0.155 p.u. Scenario 2.2: At a fixed PMSG output active power of Pg0 = 0.150 p.u., the influence of line connection reactance on the system’s SSS was analyzed. The maximum line connection reactance that satisfies the SSS criterion was calculated as tL0 = 0.138. For verification, the line connection reactance was increased from 0.130 to 0.140 p.u., and the dominant oscillation modes were calculated. At xL = 0.138, the eigenvalues of the full-order and reduced-order models were 0.163 ± j35.61 and 0.043 ± j36.080, respectively. The results indicated that the system became unstable when xL > 0.138.

Conclusions

The analytical criteria derived in this study provide an efficient approach for assessing the SSS of the PMSG-based wind farm connected to the VSC‒HVDC system. The findings of this study enhance the understanding of the mechanisms leading to oscillatory instability by revealing the relationships among key factors, such as the control parameters of PMSGs and VSC‒HVDC, PMSG output active power, and line connection reactance. The criteria provide a significant reduction in computational complexity, clear physical insights, and practical guidance for optimizing control parameters to maintain stability. The results demonstrate that adjusting parameters such as the PMSG’s DC voltage control loop, PLL settings, and the VSC‒HVDC’s AC voltage control loop can effectively improve system stability, even under high output power or weak grid connection conditions. Future research will extend these findings by investigating SSS in systems where wind farms are connected to a modular multilevel converter-based HVDC system.

Total 1