A gas chromatography-mass spectrometry (GC-MS) method for detection the peroxide explosive hexamethylene triperoxide diamine (HMTD) was established to address the difficulty of HMTD detection in practical cases. The samples were extracted with acetone, followed by centrifugation to obtain the supernatant which was then concentrated and diluted. Separation was achieved using an HP-5MS chromatographic column (30 m×0.25 mm×0.25 μm) at a flow rate of 4.0 mL/min. The samples were analyzed using electron impact ionization (EI) mode and quantified by an external standard method. HMTD exhibited good linearity within the concentration range of 1 to 100 μg/mL, with a correlation coefficient (R2) of at least 0.995. When employing blank dust as the matrix, the method demonstrated a detection limit of 0.4 μg/g in full scan mode (SCAN). However, in selective ion scanning mode (SIM), the detection limit was significantly lower at 0.01 μg/g, with a quantitation limit of 0.04 μg/g. The average recovery rate ranged from 89.15% to 95.41%, indicating good reliability of the method. Additionally, the intra-day precision ranged from 4.67% to 6.26%, while the inter-day precision varied between 4.59% and 12.69%, demonstrating favorable reproducibility of the assay. This method is simple, reliable, and highly sensitive, and has been successfully applied to detect HMTD in practical cases. It is suitable for the detection of HMTD in suspected explosives and explosive soil, meeting the needs of actual case investigations.
- Article type
- Year
Open Access
Research Article
Issue
Open Access
Research Article
Issue
A gas chromatography-tandem mass spectrometry (GC-MS/MS) based method was developed for the determination of etomidate and metomidate in e-cigarette liquid. The samples were extracted with methanol and separated on a HP-5MS column (30 m×0.25 mm×0.25 μm). Etomidate and metomidate were detected by GC-MS/MS under multiple reaction monitoring (MRM) mode, and quantified by an internal standard method. The mass spectrometry parameters, including parent ions, product ions, and collision energy, were optimized in this experiment. The results showed that etomidate and metomidate exhibited good linearity within the range of 0.1 to 10 μg/mL, with R2 no lower than 0.999. The recovery rates of spiked matrix were between 98% and 107%. The relative standard deviations (RSDs) for intra-day and inter-day precision were less than 8.83% and 9.34%, respectively. The concentrations of etomidate and metomidate in seven e-cigarette liquid samples ranged from 4.96% to 18.48%. This method is simple, easy to operate, with high extraction recovery, good reproducibility, and high sensitivity. It can be used for the detection and analysis of etomidate and metomidate in e-cigarette liquids.
京公网安备11010802044758号