Publications
Sort:
Open Access Issue
Comparison of the shaping ability of different nickel-titanium instruments in simulated root canals in resin
Journal of Prevention and Treatment for Stomatological Diseases 2019, 27(2): 95-99
Published: 20 February 2019
Abstract PDF (1.4 MB) Collect
Downloads:0
Objective

To compare the shaping ability of 3 different nickel (Ni)-titanium (Ti) systems in simulated root canals in resin and to provide a reference for clinicians.

Methods

Forty-eight resin blocks were prepared using the F360 (Komet, Brasseler GmbH & Co., Lemgo, Germany) (Group 1), F6 SkyTaper (20/06) (Komet, Brasseler GmbH & Co., Lemgo, Germany) (Group 2), F6 SkyTaper (25/06) (Komet, Brasseler GmbH & Co., Lemgo, Germany) (Group 3) and Reciproc R25 systems (VDW, Munich, Germany) (Group 4) (n=12 canals/group). The images taken before and after preparation were superimposed and analyzed by Adobe Photoshop v7.0. The amount of resin removed by each system was measured, and the centering ability was assessed. The data were statistically analyzed using SPSS 20.0.

Results

At the 1 mm point, the transportation in Group 4 [(0.10 ± 0.03) mm] was significantly greater than that in Groups 2 [(0.05 ± 0.03) mm] and 3 [(0.05 ± 0.03) mm] (P < 0.05). At the 8 mm and 9 mm points, the transportation values in Group 4 [(0.12 ± 0.06) mm and (0.13 ± 0.05) mm] were significantly higher than those in Groups 2 [(0.05 ± 0.05) mm and (0.05 ± 0.05) mm] and 3 [(0.05 ± 0.04) mm and (0.06 ± 0.05) mm] (P < 0.05). At the 10 mm point, the transportation was significantly greater in Group 4 [(0.13 ± 0.06) mm] than in Group 2 [(0.06 ± 0.06) mm].

Conclusion

F6 SkyTaper exhibits better centering ability than Reciproc.

Open Access Issue
A comparison of the effect of different nickel-titanium instruments combined with ultrasonic irrigation on root canal preparation
Journal of Prevention and Treatment for Stomatological Diseases 2019, 27(3): 167-171
Published: 20 March 2019
Abstract PDF (1.2 MB) Collect
Downloads:0
Objective

To compare the removal efficiency and the amounts of apically extruded debris using Twisted File (TF), Twisted File Adaptive (TFA), ProTaper, and ProTaper Next combined with ultrasonic irrigation and to provide an experimental basis for the selection of root canal instrumentation in the clinic.

Methods

Forty mandibular premolars were randomly divided into 4 groups (n=10 teeth per group). The canals were cut using a Twisted File, Twisted File Adaptive, ProTaper, or ProTaper Next nickel-titanium instrument. The canals were irrigated with ultrasonic irrigation. The apically extruded debris were collected in preweighted Eppendorf tubes. The amount of dental tissue removed and extruded debris were assessed with an electronic balance.

Results

The amount of tooth tissue removed in groups A, B, C and D was 20.5 ± 2.0 mg, 17.8 ± 4.2 mg, 20.8 ± 3.9 mg and 16.5 ± 2.2 mg, respectively. Combined with ultrasonic irrigation, the Twisted File and ProTaper had a better removal efficiency than the ProTaper Next(P < 0.05). There was no significant difference in the amount of extruded debris (χ2=4.057, P=0.255) among four groups.

Conclusion

The Twisted File and ProTaper had a better removal efficiency than the ProTaper Next combined with ultrasonic irrigation. There was no significant difference in the amount of extruded debris using four Nickel-titanium instruments combined with ultrasonic irrigation.

Total 2