Thermal-management systems for electric vehicles have become a key research focus for enhancing cabin thermal comfort and battery performance. This study proposes a direct-cooling system architecture to address the different temperature-response characteristics of cabins and power batteries. A dual-objective temperature-control strategy is developed based on ambient temperature, vehicle operating status, and real-time load temperature information, enabling the dynamic adjustment of thermal-control priorities between the cabin and battery to ensure optimal system performance. A thermal-management system test bench is constructed in an environmental chamber, and a simulation model of the vehicle thermal-management system is developed. Performance comparisons are conducted between the three control strategies under various driving conditions and ambient temperatures. The results demonstrate that the dual-objective strategy exhibits superior temperature-control capability and energy efficiency across different environmental conditions, along with optimal battery state-of-charge (SOC) recovery performance. Under 35 ℃ high-temperature conditions, the cabin and battery reach target temperatures within 51 s and 547 s, respectively. Under -7 ℃ low-temperature conditions, they reach preset values within 127 s and 365 s, respectively, with significantly improved SOC recovery rates. Although the dual-objective strategy slightly increases energy consumption (approximately 1.2%-3.0% higher than the cabin-priority strategy), it substantially enhances the battery thermal-control efficiency and overall system performance, demonstrating high potential for practical applications.
- Article type
- Year
Open Access
Issue
Drying is an ever-increasing demand in both industrial and agricultural fields. However, the traditional drying of heat pumps cannot fully meet the actual requirements of large-scale production, due to the low energy efficiency and serious environmental impacts. It is very necessary to develop an efficient and environment-friendly drying system. In this study, a drying bypass system of a closed-cycle heat pump was proposed for high efficiency using non-azeotropic mixed refrigerants. The heat recovery was optimized to enhance the product quality and the economic performance of the system, particularly with less energy consumption. White radish was used as the experimental material, and the optimization objectives included the heat transfer coefficient of the heat pump drying system, drying rate, dehumidification energy consumption ratio, final wet basis moisture content of the material, and exergy efficiency. Based on these indicators, kinetic and thermodynamic analysis models were developed, and experiments were conducted to investigate the effects of three factors—drying temperature, air bypass ratio, and non-azeotropic mixture ratio on the system's drying performance and energy efficiency. Experimental results show that the drying performance of the system was firstly improved and then declined, as the air bypass ratio increased. Once the air bypass ratio reached 60%, the best performance was achieved to optimize the heat transfer coefficient of the evaporator and the material drying rate. When the average temperature in the drying chamber increased to 55 ℃, the final wet basis moisture content of the white radish was further reduced to 23.4% within the same. In addition, the non-azeotropic mixed refrigerant R32/R600 was introduced to further improve energy efficiency and drying performance. There was a more homogeneous composition of the mixed refrigerant, as the xR32 increased. While the temperature glide decreased gradually. The more uniform thermal driving force was found inside the evaporator, thus improving the heat exchange efficiency and heat transfer coefficient. Furthermore, the maximum coefficient of performance (COP) of the system was achieved at the optimal R32 mass fraction of 0.70. The final content of wet basis moisture in the material decreased to the lowest level, indicating significant energy efficiency. Thermodynamic analysis revealed that the heat transfer losses in the evaporator and condenser accounted for about 50% of the total, where the condenser contributed the most (approximately 32%). The mixed refrigerants significantly improved the heat efficiency of the system. The heat efficiency reached the highest value of 40.37% when the R32 mass fraction was 0.70. There were the 67.5% and 27.0% increase, respectively, compared with the R32 mass fraction of 0.45 and 1.0. Experimental and thermodynamic analysis showed that the drying bypass system of a closed-loop heat pump with the non-azeotropic mixed refrigerant significantly improved the energy efficiency for the better performance of drying in the promising application. This finding can provide important theoretical and technical support to optimize the heat pump drying system.
京公网安备11010802044758号