Sort:
Open Access Clinical Study Issue
Classification of furcation involvement of endodontically treated mandibular first permanent molars based on cone beam CT
Journal of Prevention and Treatment for Stomatological Diseases 2023, 31(7): 488-493
Published: 20 July 2023
Abstract PDF (2.7 MB) Collect
Downloads:10
Objective

To classify the furcation involvement (FI) of endodontically treated mandibular first permanent molars based on cone beam computed tomography (CBCT), provide reference for individualized treatment of FI.

Methods

CBCT images of the FI of 164 endodontically treated mandibular first permanent molars from 163 patients in Nanjing Stomatological Hospital, Medical School of Nanjing University were collected retrospectively. On the CBCT images, the shape and extent of periapical and periodontitis bone resorption, the thickness of residual dentin in the pulp floor and root canal wall, and the periodontal bone resorption of the complete dentition were evaluated. The FI was classified into periodontal, periapical, perforated and mixed types.

Results

Among the 164 FIs of endodontically treated mandibular first permanent molars, the periapical type was the most common (41.5%), followed by the mixed type (26.2%), perforated type (18.3%), and periodontal type (14.0%). Among the 68 periapical-type FIs of endodontically treated mandibular first permanent molars, 48.5% were proper root canal filling, 44.1% were insufficient filling and 7.4% were overfilling. Among the 43 mixed-type FIs, the periodontal mixed periapical type was the most common (72.1%).

Conclusion

Detailed evaluation and classification of furcation involvement could be performed using CBCT images; therefore, the study has guiding significance for clinical treatment.

Open Access Clinical Study Issue
Effects of different scanning parameters of cone beam CT on displaying microstructure of mandible
Journal of Prevention and Treatment for Stomatological Diseases 2024, 32(12): 945-953
Published: 20 December 2024
Abstract PDF (9.6 MB) Collect
Downloads:6
Objective

To compare the effect of different scanning parameters of cone beam computed tomography (CBCT) on displaying trabecular microstructure in the anterior region of the mental foramen of the mandible, and to provide a basis for the rational selection of CBCT scanning parameters.

Methods

This study was approved by the Ethics Committee of the Affiliated Stomatological Hospital, Medical School of Nanjing University. An in vitro study was conducted using CBCT (ProMax 3D Mid) to scan eight dry human mandibular specimens with five scanning protocols: Group A: 90 kV/6. 3 mA, Group B: 90 kV/8.0 mA, Group C: 90 kV/10.0 mA, Group D: 75 kV/8.0 mA, and Group E: 60kV/8.0 mA, resulting in a total of 40 CBCT images. Entrance surface dose (ESD) and computed tomography dose index(CTDI) under different scanning conditions were recorded. The original CBCT images were imported into the image analysis software (Hiscan Analyzer) to measure four trabecular bone microstructural parameters in the region of interest of the mandible: trabecular thickness (Tb.Th), trabecular number (Tb.N), trabecular space (Tb.Sp), and bone volume/tissue volume (BV/TV). A total of 108 CBCT images were retrospectively collected from clinical implant patients using any of the 90 kV/6. 3 mA, 90 kV/8.0 mA, or 90 kV/10.0 mA scanning conditions, and the above four parameters of the region of interest of the mandible were also measured. SPSS 26.0 software was used to compare the differences in the four trabecular bone microstructural parameters between the CBCT images of the mandibular specimens in vitro and clinical patients in vivo.

Results

The in vitro study results showed that reducing the tube voltage and tube current would lead to a decrease in the ESD and CTDI. When the tube voltage was maintained at 90 kV and the tube current was changed, BV/TV, Tb.N, and Tb.Th values increased with the increase of tube current;Tb.Sp values decreased with the increase of tube current, but there was no statistically significant difference in the four bone morphological parameters (P>0.05). When the tube current was maintained at 8.0 mA and the tube voltage was altered, BV/TV and Tb.N decreased with the increase of tube voltage, Tb.Sp values increased with the increase of tube voltage, and BV/TV, Tb.N, and Tb.Sp showed statistically significant differences (P<0.05). In clinical patients undergoing CBCT scanning, when the tube voltage was90 kV and the tube current was different (6. 3, 8.0, 10.0 mA), there was no statistically significant difference in the four bone morphological parameters (P>0.05).

Conclusion

In this study, when the tube voltage was fixed at 90 kV, there was no difference in the trabecular microstructure of the anterior region of the mandible when the tube current was increased. When CBCT scanning of clinical patients needs to show the trabecular microstructure of the anterior region of the mandible, the tube current can be appropriately reduced to decrease the radiation dose received by the patient. Thus, it is recommended to use the parameters 90 kV and 6. 3 mA for CBCT scanning.

Total 2