Recognition methods of electromagnetic transients (EMT) have been widely used in power systems with the assumption that training and testing data are drawn from the same probability distribution. However, that assumption is hard to satisfy in industrial applications because the distribution of measured EMT testing data generally changes over time. The performance of these methods gradually deteriorates with the distribution shift. The phenomenon limits application of EMT recognition methods. Therefore, this paper proposes a transfer learning-based recognition network (TLRN) for EMT to break the limitation. It consists of a feature extractor, EMT recognizer, domain recognizer, and maximum mean discrepancy (MMD). The feature extractor is constructed to learn features of EMT automatically. The domain recognizer and MMD make features learned by the feature extractor domain invariant. Based on domain invariant features, the EMT recognizer achieves accurate EMT recognition, despite the distribution discrepancy between EMT training and testing data. TLRN maintains satisfactory EMT recognition performance by updating periodically with an unsupervised learning strategy. Using EMT datasets measured from different substations, scenario experiments, and experiment comparisons are conducted, and the recognition performance of the proposed TLRN is demonstrated.
- Article type
- Year
Open Access
Regular Paper
Issue
Open Access
Regular Paper
Issue
Data-driven detection models for voltage disturbance in power systems have performed exceptionally over the years. However, they require a large number of samples for training, and the monitoring systems that are operated in substations cannot easily meet this requirement. Therefore, few-shot voltage disturbance detection is urgently needed. In this study, a new detection framework and its episodic training mechanism are proposed to address the above need. The proposed framework is comprised of a short-time Fourier trans-form (STFT), a feature extractor, and a feature evaluator. STFT converts a voltage disturbance into a time–frequency matrix to enrich its information. Then, the feature extractor learns features from the time–frequency matrix. Finally, the feature evaluator identifies the voltage disturbance by evaluating the similarities between its feature and the features of a support set. An episodic training mechanism is proposed to enable the framework to learn how to evaluate similarities between the voltage disturbance to be detected and the voltage disturbance in the support set. Experiments on two measured voltage disturbance datasets demonstrate that the framework can detect a voltage disturbance type on the basis of a few samples of that type in the support set. The proposed framework provides a competitive solution for the detection of few-shot voltage disturbances and other similar electricity data that are difficult to collect.
Open Access
Regular Paper
Issue
DC line protection with high speed and strong robustness against high fault resistance is essential in high-voltage direct current (HVDC) grids. The conventional voltage-derivative-based protections for DC lines exhibit the problem of low reliability on the occurrence of high-impedance faults. In this paper, fault traveling waves at the fault point and at the line side of the DC reactor are first analyzed using phase-modal transformation. Based on the theoretical analysis of the modal fault-component voltages at the line side of the DC reactor, a novel hybrid protection scheme utilizing the single-ended rate of change of voltage (ROCOV) and waveform similarity coefficient is proposed. It utilizes the hybrid ROCOV criterion and waveform similarity coefficient to identify the faulted line and the amplitudes of the 0- and 1-mode fault-component voltages to identify fault type, and the polarities of the 0- and 1-mode fault-component voltages to identify faulted pole. Simulations under various fault conditions verify that the proposed protection scheme can achieve fast and reliable identification of faulted line, fault type, and faulted pole in 1 ms, and effectively improve the reliability against high-impedance faults up to 1200 Ω.
京公网安备11010802044758号