To investigate the performance of a Fuel Thermal Management System (FTMS) with expendable heat sink under multiple temperature limit points, and to extend the system's longest normally working time (thermal endurance) by optimizing the utilization of expendable heat sink, a simulation flow path using Liquid Methane (LM) as the expendable heat sink was constructed. Initially, the characteristics of hot fuel return were analyzed. The results indicate that the fuel heat sink consumption rate increases with increasing supply pump flow rate during normal operations. When the ram air is insufficient, the fuel return temperature to the fuel tank becomes the main limit temperature of the FTMS, and to meet the temperature requirement of hot fuel return, the system optimal supply pump flow rate is too high, resulting in a poor heat dissipation performance. In this case, the use of LM can not only cool the hot fuel return, but also further reduce the fuel heat sink consumption by reducing the optimal supply pump flow rate. Subsequently, the effect of the Middle Fuel Return Branch (MFRB) on system heat dissipation performance was explored. The results show that once the ram air is insufficient, the MFRB can not only increase the heat dissipation through combustion fuel, but also further enhance the system heat dissipation capability by decreasing the optimal supply pump flow rate as well. The fuel heat sink consumption rate under the standard condition without LM can be reduced by 17.62% in the new flow path. Next, the characteristics of LM supply flow were analyzed. The results demonstrate that the LM supply flow rate can be divided into the high efficiency, general, and low efficiency zones for LM according to the effect of using LM. Finally, a new dynamic supply strategy of LM was proposed. Under the standard condition, the thermal endurance can be improved by 9.21%and 27.44% compared to the constant low flowand high flow LM supply strategies, respectively.
- Article type
- Year
With the rapid increase in aircraft thermal loads and the flight Mach number, combustion fuel and ram air can no longer effectively cool the fuel thermal management system (FTMS). Recently, hot fuel return has become an important way to enhance the cooling capacity of the FTMS, and the regulation of the hot fuel return flow has garnered significant attention. However, the impact of the hot fuel return flow on the limited temperatures still requires systematic research, and the thermal load limits of the FTMS have not been explored. Therefore, in this study, the hot fuel return characteristics of the FTMS with multiple temperature limit points were investigated to improve system performance.
Considering the scalability of the models, a steady-state simulation model for the FTMS was developed using Python based on the thermal fluid network method and solved using the damped Newton method to guarantee the convergence of the flow and heat transfer iterations. In addition, the program was verified via experiments to guarantee its accuracy. A complete FTMS flow path was designed, and a standard condition was set for subsequent calculations. First, the temperature variations of the temperature limit points with the hot fuel return flow were calculated under the standard condition. Subsequently, by increasing the airborne thermal load under the standard condition, the maximum airborne thermal load that the system can withstand under the action of the hot fuel return (airborne thermal load limit) was investigated, and the occurrence condition of the limit state was analyzed. Lastly, the maximum total thermal load for normal operations (total thermal load limit) was explored under the standard condition, and the condition for reaching the total thermal load limit was discussed by changing the aeroengine thermal load.
The increase of the hot fuel return flow may not decrease all the limited temperatures, even inducing the outlet temperature rises of the fuel tank and the hot fuel return valve. Excessive or insufficient hot fuel return flow may result in the overtemperature of the FTMS, and there exists a change interval for it to meet the multiple temperature limitations. For the outlet temperatures of the airborne thermal load heater and the fuel nozzle, there exists a critical flow of the hot fuel return, which indicates that the two outlet temperatures will not change once the hot fuel return flow reaches the critical flow. Combined with the outlet temperature rises of the fuel tank and the hot fuel return valve, when the hot fuel return flow surpasses its critical value, further increasing the hot fuel return flow will only increase the risk of system overtemperature. Moreover, the FTMS exhibits similar hot fuel return characteristics under different airborne thermal loads, and the critical flow of the hot fuel return rises with increasing airborne thermal load. However, as the critical flow of the hot fuel return rises slower than the lower boundary of the limited interval for the hot fuel return flow with the increased airborne thermal load, the airborne thermal load limit corresponds to the critical state when the size of the limited interval for the hot fuel return flow mutates into zero, and the lower boundary of the limited interval of the hot fuel return flow is just the system critical flow of the hot fuel return in this condition. Furthermore, the calculation results reveal that when the outlet temperatures of the airborne thermal load heater and the fuel nozzle reach their respective limit values in the limit state, the total thermal load limit can be achieved. In addition, to fully utilize the total thermal load limit of the FTMS under the action of an unreasonable aeroengine thermal load, the intermediate loop in this paper can be used to achieve the mutual transfer of the system thermal loads by the heat exchangers and refrigerating devices. As long as the total thermal load does not exceed the total thermal load limit, the FTMS can ensure that the system works normally through the intermediate loop to adjust the new aeroengine thermal load transferred into the fuel.
This study explains the temperature variation regularity of multiple temperature limit points and the thermal load limits under the effect of the hot fuel return, providing a reference for the design of the thermal load distribution and the regulation strategy of the hot fuel return flow.