Because of its controlled power factor and no commutation failure, current source converter (CSC) made up of reverse-blocking IGCTs (RB-IGCTs) offers broad application prospects in the field of HVDC system. Valve voltage and power operating range as the most important operating characteristics should be paid attention to but they are always contradictory. First, the relationship between valve voltage and modulation index is obtained. In particular, valve voltage of converter under the three typical modulation methods is compared, analyzed, and verified. Second, with the help of the independent control strategy and coordinated control strategy of both ends, power operating ranges of the three modulation methods are comprehensively analyzed and compared. Third, in order to solve power coupling at a low active power, the improved coordination control strategy at both ends in this paper is proposed and the relationships among active power, reactive power, DC current and phase angle difference are given in detail. Finally, a 500 kV/3 kA simulation system was built in PSCAD/EMTDC to obtain comparison results of the key operating characteristics of CSC under different modulation methods and the converter can realize unity power operation under random active power after adopting the improved coordinated control strategy, and DC current does not decrease to zero, verifying effectiveness of the coordinated control strategy.
- Article type
- Year
Open Access
Regular Paper
Issue
Open Access
Regular Paper
Issue
Pulse width modulated current-source converter (PWM-CSC) has great prospects in high voltage direct current transmission system (HVDC) due to its attractive features, such as flexible control characteristics, ability to avoid commutation failure, and lower cost. However, valve voltage of the PWM-CSC is the jump value between filter capacitors line-voltage and zero voltage due to its bypass operation, resulting in high peak voltage withstand by the converter for a rated HVDC system and high voltage ripper ratio. In order to solve these issues, an improved modulation method called specific carrier frequency of SPWM is proposed. After adopting the improved modulation method, the number of the reverse blocking integrated gate commutated thyristor (RB-IGCT) in series can reduce by 31.5% under unity power factor operation and the value of the dc choke can reduce by about 78.6% compared to traditional modulation methods, improving practicability of engineering application. Moreover, active power and reactive power operating range are derived under different modulation methods and the relationship of the power factor, modulation in q-axis and DC current are studied. Finally, effectiveness of the improved modulation method and comparisons of power operating range are verified in PSCAD/EMTDC.
京公网安备11010802044758号