Sort:
Open Access Regular Paper Issue
Design Considerations on Voltage and Current Transfer Ratio of High-frequency Transformers
CSEE Journal of Power and Energy Systems 2025, 11(1): 447-457
Published: 17 November 2023
Abstract PDF (2.2 MB) Collect
Downloads:106

A high frequency (HF) transformer is key equipment for dc-dc converter to achieve galvanic isolation and voltage transformation. As operating frequency increases, voltage and current transfer ratio of HF transformer may significantly deviate from the turn ratio due to parasitic effects, failing to transfer expected voltage and current from the primary side to the secondary side. In this paper, design considerations on voltage and current transfer ratio of the HF transformer are investigated to obtain expected transfer performance. By revealing parasitic effects on transfer characteristic (TC) of the HF transformer with load, deviation between voltage/current transfer ratio and turn ratio is correlated with the ratio of voltage/current TC resonant frequency and operating frequency. Accordingly, constraints for parasitic parameters to obtain expected transfer ratio are proposed, and practical measures to achieve improvements in transformer design are discussed. A 20kHz HF transformer prototype is used as an application, by which evaluations on deviation of voltage/current transfer ratio and turn ratio are verified, and voltage/current transfer performance of the prototype are effectively improved by optimal design based on the proposed principles.

Open Access Regular Paper Issue
Parameter Design and Transfer Characteristic Optimization of Floating-ground Capacitive Voltage Divider for Wideband High Voltage Measurement
CSEE Journal of Power and Energy Systems 2025, 11(4): 1693-1703
Published: 03 March 2023
Abstract PDF (3.9 MB) Collect
Downloads:101

Voltage measuring equipment in power grids often requires capacitive voltage dividers to realize conversion of high voltage electrical quantities to low voltage signal quantities. The new floating-ground capacitive voltage divider (FG-CVD) can eliminate original lumped capacitors and its supporting insulation structures by adopting precisely designed parasitic capacitance as a high voltage arm capacitor, which can greatly save cost and volume. However, the utilization of parasitic capacitance not only makes FG-CVD sensitive to external conductor interference, but also causes transient waveform distortion, especially when the connecting lead between the FG-CVD and high-voltage conductor is lengthy. On the basis of transfer characteristic analysis, this paper proposes a complete parameter design method for FG-CVD to improve stability of its transfer ratio under interference of the external conductor. Moreover, by establishing a wideband equivalent model with lead inductance, the transient waveform distortion problem of FG-CVD is well explained, and a resistance compensation scheme is also proposed to reduce ratio error. Finally, a 500:1 FG-CVD prototype with a measurement bandwidth of 2MHz is developed. Experimental results show the prototype has high accuracy in both power frequency and lightning pulse voltage measurement, and ratio error decreases from 20.33% to less than 1.3%.

Open Access Issue
Modeling of High-frequency Electromagnetic Oscillation for DC Fault in MMC-HVDC Systems
CSEE Journal of Power and Energy Systems 2023, 9(3): 1151-1160
Published: 09 December 2022
Abstract PDF (2.9 MB) Collect
Downloads:59

DC short-circuit faults pose a hazard to the operation of a modular multilevel converter (MMC)-based high voltage direct current (HVDC) system, necessitating reliable fault clearing solutions with rapid reaction. However, because the parasitic capacitances of the main equipment oscillate with the lumped inductances of the HVDC system, strong electromagnetic oscillations with multiple frequencies occur during clearance transients. These oscillations will disturb the HVDC system's protection and control systems. Therefore, this paper focuses on the modeling of these oscillations. First, an equivalent circuit for the MMC-based HVDC system is proposed, taking into account the parasitic capacitances of the system's major components, such as DC reactors, connecting cables, and DC circuit breakers (DCCBs). Second, four distinct oscillation stages are postulated based on action coordination of MMCs and DCCBs, and the associated analytical equations for the oscillation frequencies are derived. Third, a 200 kV MMC-based DC converter station is subjected to an 6ms/6kA pole-to-pole (PTP) short-circuit test. Electromagnetic oscillations have a frequency range of several kHz to several hundreds of kHz. The measured waveforms correspond well with simulated results, including the parasitic characteristics. Additionally, the relative errors between the simulated and measured frequencies are less than 5%.

Open Access Issue
Circuit Model with Current Interruption for Hybrid High Voltage DC Circuit Breakers to Achieve Precise Current Experiments
CSEE Journal of Power and Energy Systems 2022, 8(4): 1250-1260
Published: 06 October 2020
Abstract PDF (4.5 MB) Collect
Downloads:55

The current interruption test based on an L⁢C resonance circuit for hybrid DC circuit breakers (HVDC CBs) is widely employed to characterize the current interruption capability of CBs. In order to ensure a high-fidelity replica of the fault current in a high voltage application, this paper first proposes an equivalent model of the test circuit, where not only parasitic resistances but also the threshold voltages and on-state resistances of various semiconductor devices are considered. Moreover, the analytical formula of the test current is derived by including the working principle of the HVDC CB. Secondly, the parameter extraction method, which combines finite element analysis and measurements by an impedance analyzer, is given in this paper. The extracted result implies that, in current interruption transients, equivalent resistances of 500 kV CB are as large as 535 m Ω, which have a significant influence on current waveforms. Thirdly, the 34 kV/25 kA current interruption test for the 500 kV CB is conducted. The measured results are proved to be consistent with the analytical results obtained from the proposed model, and the relative error is less than 2%.

Total 4