A newly developed open-end intracranial hematoma drainage tube
Brain Science Advances 2016, 2(2): 150-152
Published: 01 June 2016
Abstract PDF (528.5 KB) Collect
Downloads:59
Objective:

To design a new open-end intracranial hematoma drainage tube for clinical application.

Methods:

The newly developed device consists of two parts: the plunger and barrel. On one side, the barrel is bullet shaped with an opening tip. The plunger is located in the middle cavity of the tube barrel and extended out at the open-end. It was designed for strengthening the tube barrel and for convenience in performing the drainage procedure. It can be used by inserting the drainage tube into the lesion and pulling out the plunger, whereby blood will forcefully rise up inside the barrel, providing a satisfactory outcome. It is made for effusion drainage purposes. During the procedure, the drainage tip is placed at the deepest part of the intracranial hematoma to completely drain the blood. Moreover, the plunger fits tightly in the tube, preventing leakage during the operation. With the use of the device, brain can be separated. In addition, the device can help reduce the risk of cerebral damage because of the small operating area. The barrel sidewall has matching opening holes bilaterally and equally for exchanging substances between the inner and outer parts. The overlapping ratio in each horizontal pair is around 1/3–1/2. Each pair on the opposite side will form a different pressure. Thus, the opening holes will not easily get blocked with blood clot.

Results:

Blood and accumulated liquid from the deepest part of the intracranial hematoma can be directly drawn through the drainage tube without damaging a large area. The tube does not get blocked easily and allows for complete removal of the hematoma.

Conclusions:

The device is asuitable instrument for clinical application.

Open Access Short Communication Issue
A new drainage tube device
Brain Science Advances 2016, 2(1): 71-73
Published: 01 March 2016
Abstract PDF (879 KB) Collect
Downloads:59
Objective:

Drainage tubes (e.g., intracranial, abdominal cavity and thoracic) are commonly used to drain blood and fluid collections after surgery. It usually fails due to the lack of fixation perpendicular to the skin and the variety of tube materials. The objective of the article is to describe a new drainage tube device.

Methods:

This new device consists of a drainage tube fixator and diverter with a rotating handle. The fixator and diverter are fixed to the skin with a pair of wings, and the base comprises acircular arc with chamfering of the edge. The removable stopper and plastic diverter have a memory function. There are 2 holes on either side of the wings, by which they can be sewn to the skin or stapled for strength and stability.

Results:

The removable limiting stopper and plastic diverter with memory function work together to ensure that the drainage tube is firmly fixed. Therefore, the tube will not move either vertically or horizontally on the skin. Moreover, the device is fit for drainage tubes with different specifications and materials.

Conclusions:

The limiting stopper can be moved easily, which is conducive to local skin disinfection around the drainage tube. The device deserves clinical promotion.

Total 2