Infectious diseases (e.g., coronavirus disease 2019) dramatically impact human life, economy and social development. Exploring the low-cost and energy-saving approaches is essential in removing infectious virus particles from indoors, such as in classrooms. The application of air purification devices, such as negative ion generators (ionizers), gains popularity because of the favorable removal capacity for particles and the low operation cost. However, small and portable ionizers have potential disadvantages in the removal efficiency owing to the limited horizontal diffusion of negative ions. This study aims to investigate the layout strategy (number and location) of ionizers based on the energy-efficient natural ventilation in the classroom to improve removal efficiency (negative ions to particles) and decrease infection risk. Three infected students were considered in the classroom. The simulations of negative ion and particle concentrations were performed and validated by the experiment. Results showed that as the number of ionizers was 4 and 5, the removal performance was largely improved by combining ionizer with natural ventilation. Compared with the scenario without an ionizer, the scenario with 5 ionizers largely increased the average removal efficiency from around 20% to 85% and decreased the average infection risk by 23%. The setup with 5 ionizers placed upstream of the classroom was determined as the optimal layout strategy, particularly when the location and number of the infected students were unknown. This work can provide a guideline for applying ionizers to public buildings when natural ventilation is used.
- Article type
- Year
Open Access
Research Article
Issue
Open Access
Research Article
Issue
Heating, ventilation and air conditioning (HVAC) systems are the most energy-consuming building implements for the improvement of indoor environmental quality (IEQ). We have developed the optimal control strategies for HVAC system to respectively achieve the optimal selections of ventilation rate and supplied air temperature with consideration of energy conservation, through the fast prediction methods by using low-dimensional linear ventilation model (LLVM) based artificial neural network (ANN) and low-dimensional linear temperature model (LLTM) based contribution ratio of indoor climate (CRI(T)). To be continued for integrated control of multi-parameters, we further developed the fast prediction model for indoor humidity by using low-dimensional linear humidity model (LLHM) and contribution ratio of indoor humidity (CRI(H)), and thermal sensation index (TS) for assessment. CFD was used to construct the prediction database for CO2, temperature and humidity. Low-dimensional linear models (LLM), including LLVM, LLTM and LLHM, were adopted to expand database for the sake of data storage reduction. Then, coupling with ANN, CRI(T) and CRI(H), the distributions of indoor CO2 concentration, temperature, and humidity were rapidly predicted on the basis of LLVM-based ANN, LLTM-based CRI(T) and LLHM-based CRI(H), respectively. Finally, according to the self-defined indices (i.e., EV, ET, EH), the optimal balancing between IEQ (indicated by CO2 concentration, PMV and TS) and energy consumption (indicated by ventilation rate, supplied air temperature and humidity) were synthetically evaluated. The total HVAC energy consumption could be reduced by 35% on the strength of current control strategies. This work can further contribute to development of the intelligent online control for HVAC systems.
京公网安备11010802044758号