Research Progress on Electrochemical Paper-Based Analytical Devices for the Detection of Pesticide Residues

Yanqing LI Xinrong ZONGSi’an CHENMin ZHANG ( )
College of Food Science and Engineering, Northwest A&F University, Yangling 712100, China
Show Author Information

Abstract

The development of pesticides has significantly advanced global agricultural production, but the ensuing problem of pesticide residues poses a severe threat to human health. So, there is an urgent need to establish a rapid, accurate, sensitive, cost-effective and on-site method for large-scale detection of pesticide residues. Electrochemical paper-based analytical devices (ePADs) represents a highly sensitive and portable microanalysis system, which uses paper as a substrate and relies on a capillary force to drive the fluid for the separation and detection of samples. The diversity of pesticides and agricultural products and the complexity of matrices impose high requirements on the sample preparation procedure. This article summarizes the preparation process of ePADs from the aspects of paper selection, the establishment of hydrophilic and hydrophobic channels, the integration of separation zones, and electrode printing. Subsequently, this paper establishes the relationship between pesticide detection and chip preparation based on the mechanism of electrochemical detection of pesticides. Finally, it discusses the advantages, challenges and future prospects of ePADs with a view to providing theoretical reference for enhanced application of ePADs in the field of pesticide residue detection.

CLC number: TS255.54 Document code: A Article ID: 1002-6630(2024)15-0252-11

References

【1】
【1】
 
 
Food Science
Pages 252-262

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LI Y, ZONG X, CHEN S, et al. Research Progress on Electrochemical Paper-Based Analytical Devices for the Detection of Pesticide Residues. Food Science, 2024, 45(15): 252-262. https://doi.org/10.7506/spkx1002-6630-20230915-133

1103

Views

30

Downloads

0

Crossref

0

Scopus

1

CSCD

Received: 15 September 2023
Published: 15 August 2024
© Beijing Academy of Food Sciences 2024.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).