AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Analysis & Detection | Publishing Language: Chinese | Open Access

Optimization of the National Standard Method for Salmonella Identification Using Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry

Jie ZHANG Yalun ZHANGTao ZHANGChen CHENZilun ZHANGWei ZHOU ( )
Hebei Food Safety Key Laboratory, Key Laboratory of Special Food Supervision Technology, State Administration for Market Regulation, Hebei Engineering Research Center for Special Food Safety and Health, Hebei Food Inspection and Research Institute, Shijiazhuang 050227, China
Show Author Information

Abstract

The rapid identification of Salmonella, a significant foodborne pathogen, is of significant importance. To establish a new method for identifying Salmonella based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), this study optimized culture medium type, incubation time, bacterial lysis methods, and instrumental parameters. The results showed that compared to the national standard method GB/T 33682-2025 General microorganism identification method with matrix-assisted laser desorption/ionization time of flight mass spectrometry, the recovery rate increased from 54.7% to 84.7% after replacing the culture medium with nutrient agar. Increasing the incubation time from 24 to 48 h increased the average identification score by 7.0%, from 2.203 to 2.355. Optimizing lysis methods elevated the average identification score by 19.0%, from 1.898 to 2.259. When the instrumental parameters were adjusted to 50% laser energy and a laser wavelength of 370 nm, the average identification score increased to 2.211. Compared to its original version specified in GB/T 33682-2025, the established MALDI-TOF/TOF MS method exhibited improved accuracy and reliability in Salmonella identification.

CLC number: TS207.4 Document code: A Article ID: 1671-5187(2026)02-0024-06

References

【1】
【1】
 
 
Journal of Dairy Science and Technology
Pages 24-29

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG J, ZHANG Y, ZHANG T, et al. Optimization of the National Standard Method for Salmonella Identification Using Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry. Journal of Dairy Science and Technology, 2026, 49(2): 24-29. https://doi.org/10.7506/rykxyjs1671-5187-20251118-080

36

Views

0

Downloads

0

Crossref

Received: 18 November 2025
Published: 01 March 2026
© Bright Dairy & Food Co., Ltd. 2026.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).