AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Analysis & Detection | Publishing Language: Chinese | Open Access

Rapid Detection of Exogenous Bovine Insulin in Camel Milk Based on Dispersive Liquid-Liquid Microextraction

Xinyue YANG Shuangyu CAOYankun ZHAONa JIANG Munira·DILXATYating WUXianlan MAHe CHEN ( )
Laboratory of Quality and Safety Risk Assessment for Agro-products (Ürümqi), Ministry of Agriculture and Rural Affairs, Key Laboratory of Agro-products Quality and Safety of Xinjiang, Institute of Quality Standards & Testing Technology for Agro-products, Xinjiang Academy of Agricultural Sciences, Ürümqi 830091, China
Show Author Information

Abstract

To addresses technical bottlenecks such as the complexity of the camel milk matrix and the interference of endogenous proteins with target detection, this study established an analytical method to detect exogenous bovine insulin in camel milk using dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography (HPLC). The extraction conditions and the instrumental parameters were optimized. The results showed that efficient enrichment and accurate quantification of target analytes in complex milk matrices were achieved by HPLC combined with DLLME using 0.01 mol/L HCl as the extractant, volume fraction 60% aqueous acetone as the extraction solvent, and n-hexane as the separation phase. The method exhibited good linearity for bovine insulin over the concentration ranges of 5-500 μg/mL (R2 = 0.999). Recoveries for blank sample of Bactrian camel milk from Dabancheng District, Ürümqi ranged from 64.1% to 86.9% at spiked levels of 5, 50 and 500 μg/mL, with relative standard deviations (RSDs) of 4.9%-12.4%. The limit of detection and limit of quantification were 0.5 and 5 μg/mL, respectively. The DLLME-HPLC method is characterized by simple operation, short pretreatment time, and high analytical efficiency, providing technical support for rapid screening of exogenous bovine insulin in camel milk.

CLC number: TS252.7; O657 Document code: A Article ID: 1671-5187(2026)02-0030-07

References

【1】
【1】
 
 
Journal of Dairy Science and Technology
Pages 30-36

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
YANG X, CAO S, ZHAO Y, et al. Rapid Detection of Exogenous Bovine Insulin in Camel Milk Based on Dispersive Liquid-Liquid Microextraction. Journal of Dairy Science and Technology, 2026, 49(2): 30-36. https://doi.org/10.7506/rykxyjs1671-5187-20251104-078

106

Views

0

Downloads

0

Crossref

Received: 04 November 2025
Published: 01 March 2026
© Bright Dairy & Food Co., Ltd. 2026.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).