AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Analysis & Detection | Publishing Language: Chinese | Open Access

Determination of Erythrosine Content in Fermented Milk by Reversed-Phase High Performance Liquid Chromatography

Jing CHEN Guoxia DUANLijun LIUCuizhi LI ( )Zhiyong LÜ
Inner Mongolia Yili Industrial Group Co. Ltd., Hohhot 010110, China
Show Author Information

Abstract

A reversed-phase high performance liquid chromatographic (HPLC) method was established for the determination of erythrosine in fermented milk. After enzymatic hydrolysis, the sample was extracted with anhydrous ethanol, and purified by solid phase extraction using an HLB column under alkaline conditions. The separation was performed on a C18 reverse-phase column by gradient elution using a mobile phase comprising 20 mmol/L ammonium acetate buffer solution (pH 6.5) and methanol. The detection wavelength was set at 520 nm, and quantification was performed by the external standard method. The results showed that the linear range for erythrosine was 0.05–20.00 μg/mL. The limit of quantitation (LOQ) and the limit of detection (LOD) of erythrosine in fermented milk samples were 0.2 and 0.1 mg/kg, respectively. The recoveries from fermented milk samples spiked at levels of 0.2–2.0 mg/kg were 96.5%–105.6%, and the relative standard deviations (RSD) were 1.87%–2.21%. The method is simple and accurate, has high recovery and good repeatability, and is suitable for the determination of erythrosine in fermented milk.

CLC number: TS252.7 Document code: A Article ID: 1671-5187(2023)01-0041-06

References

【1】
【1】
 
 
Journal of Dairy Science and Technology
Pages 41-46

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
CHEN J, DUAN G, LIU L, et al. Determination of Erythrosine Content in Fermented Milk by Reversed-Phase High Performance Liquid Chromatography. Journal of Dairy Science and Technology, 2023, 46(1): 41-46. https://doi.org/10.7506/rykxyjs1671-5187-20221025-064

320

Views

4

Downloads

0

Crossref

Received: 25 October 2022
Published: 01 January 2023
© Bright Dairy & Food Co., Ltd. 2023.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).