AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (9.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Frequency-Sweeping Interferometry for Intersatellite Baseline Metrology in Array Telescope Formation

Wenjun Chen1, Xiaoping Li1, Zhongwen Deng1( ), Chenxu Wang1, Shuwei Zhang1, Haifeng Sun1, Hengkang Zhang2, Lin Li2, Li Wang2, Hai Gong3, Herman Koara4, Gleb Vdovin5, Weimin Bao1,6
School of Aerospace Science and Technology, Xidian University, Xi’an 710071, China
Space Optoelectronic Measurement and Perception Lab, Beijing Institute of Control Engineering, Beijing 100190, China
Huzhou Research Institute of Zhejiang University, Zhejiang University, Huzhou 313000, China
College of Control Science and Engineering, Zhejiang University, Hangzhou 310000, China
Faculty of Mechanical Engineering, Delft University of Technology, 2628CD Delft, The Netherlands
China Aerospace Science and Technology Corporation, Beijing 100048, China
Show Author Information

Abstract

Space-based distributed array telescope formations hold substantial potential for deep space exploration, with their performance highly dependent on precise baseline measurements between subtelescopes. This study presents a double-sideband frequency-sweeping interferometry (DSB-FSI) technique based on electro-optic modulation for intertelescope baseline measurements. To address the lack of on-orbit frequency-sweep calibration references, a Fabry–Pérot etalon is used for real-time in situ frequency-sweep rate calibration. Experimental results show that the Fabry–Pérot etalon effectively calibrates the frequency-sweep rate of the DSB-FSI system, reducing long-term baseline measurement drift error from 20.11 to 13.38 μm and decreasing maximum measurement deviation from 18.03 to 13.14 μm over a 5.7-m baseline. Metrological calibration confirms that the calibrated system achieves a baseline measurement accuracy of 44.30 μm over a 10-m range, with excellent dynamic measurement performance for monitoring baseline variations. The DSB-FSI technique is expected to provide a reliable solution for the high-precision intertelescope baseline measurements in “MEAYIN” (Multiple-Spacecraft Exoplanet Aperture Synthetic Interferometer) project, thus supporting the advancement of space-based distributed array telescope formation technologies.

References

【1】
【1】
 
 
Space: Science & Technology
Article number: 0482

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Chen W, Li X, Deng Z, et al. Frequency-Sweeping Interferometry for Intersatellite Baseline Metrology in Array Telescope Formation. Space: Science & Technology, 2026, 6: 0482. https://doi.org/10.34133/space.0482

3

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 10 October 2025
Revised: 04 December 2025
Accepted: 19 January 2026
Published: 04 March 2026
© 2026 Wenjun Chen et al. Exclusive licensee Beijing Institute of Technology Press. No claim to original U.S. Government Works.

Distributed under a Creative Commons Attribution License (CC BY 4.0).