Abstract
Physical underwater barriers can obstruct navigation and aquaculture operations and often require substantial fixed infrastructure. This study presents an electric-eel-inspired bioelectric barrier prototype that produces controllable pulsed electric fields from a low-voltage supply. The biomimetic contribution has two components: reproduction of the measured high-voltage electric-organ-discharge (EOD) timing (100 Hz repetition and 2.5 ms active width), and a six-stage Marx cascade that provides an engineering analogue of serial electrocyte voltage summation. With a 5–10 V DC input, the prototype generated stable pulses across 28–500 Ω resistive loads and reached 53 V, corresponding to a peak voltage-transfer ratio of 88% relative to the ideal sixfold sum. The measured time-averaged load power ranged from 0.3 to 14.5 W. Prototype experiments show clear amplitude-dependent behavioral responses in fish and stronger responses to EOD-like pulses than to DC stimulation under the tested conditions. These results demonstrate the circuit-level feasibility of a low-power, contactless bioelectric barrier and provide a technical basis for bioinspired underwater defense.
京公网安备11010802044758号
Comments on this article