AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (9.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Bearing Capacity Research of Anchor-Surrounded Pier Foundation in Transmission Lines Engineering

Yuan Wang1, Hao Chen1, Fengjuan Tao2( ), Liming Yi1, Haini He2
Power China Hubei Electric Engineering Co., Ltd., Wuhan 430040, P. R. China
School of Civil Engineering, Wuhan University, Wuhan 430072, P. R. China
Show Author Information

Abstract

The anchor-surrounded pier foundation is a new type of foundation form in transmission line engineering, and its deformation damage mode and composite bearing characteristics are still unclear. Combined with the laboratory test and numerical simulation method, the load test of the anchor-surrounded pier foundation is carried out. The results show that: The anchor-surrounded pier foundation in the undercropping medium-weathered and strongly weathered rock layer in the resistance to pullout loading curves are respectively "steeply variable" and "slowly variable"; The damage modes are "short pile dislodged damage, accompanied by anchor fracture" and "short pile dislodged damage along the periphery of group anchors", respectively; The compressive loading curves of composite foundations in different underlying rock formations are "steep change type", and the damage modes are "short pile stabbing damage". The ultimate bearing capacity of a single pile increases with the increase of the diameter of the short pile, the depth of the socketed rock, and the thickness of the soil layer on the side of the pile. The single pile pullout bearing capacity of anchor is about the sum of the pullout bearing capacity of traditional pure short pile and pure anchor foundation, and the single pile compressive bearing capacity is slightly larger than that of the traditional pure short pile foundation; the horizontal load greatly weakened the composite foundation bearing capacity, and it should be paid attention to.

CLC number: TU476 Document code: A Article ID: 1673-0836(2026)01-0279-12

References

【1】
【1】
 
 
Chinese Journal of Underground Space and Engineering
Pages 279-290

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang Y, Chen H, Tao F, et al. Bearing Capacity Research of Anchor-Surrounded Pier Foundation in Transmission Lines Engineering. Chinese Journal of Underground Space and Engineering, 2026, 22(1): 279-290. https://doi.org/10.20174/j.JUSE.2026.01.29

483

Views

3

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 18 April 2025
Published: 01 February 2026
© 2026 Chinese Journal of Underground Space and Engineering

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).