AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.4 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Publishing Language: Chinese | Open Access

Determination Method of Peroxide Explosive HMTD by GC-MS

Hua ZHOU1( )Liang ZHANG2Yue XU1Wenjun TAO1
Guangdong Province Huizhou Municipal Public Security Forensic Science Centre, Huizhou 516000, Guangdong, China
Criminal Technology Center, Guangdong Provincial Public Security Department, Guangzhou 510050, China
Show Author Information

Abstract

A gas chromatography-mass spectrometry (GC-MS) method for detection the peroxide explosive hexamethylene triperoxide diamine (HMTD) was established to address the difficulty of HMTD detection in practical cases. The samples were extracted with acetone, followed by centrifugation to obtain the supernatant which was then concentrated and diluted. Separation was achieved using an HP-5MS chromatographic column (30 m×0.25 mm×0.25 μm) at a flow rate of 4.0 mL/min. The samples were analyzed using electron impact ionization (EI) mode and quantified by an external standard method. HMTD exhibited good linearity within the concentration range of 1 to 100 μg/mL, with a correlation coefficient (R2) of at least 0.995. When employing blank dust as the matrix, the method demonstrated a detection limit of 0.4 μg/g in full scan mode (SCAN). However, in selective ion scanning mode (SIM), the detection limit was significantly lower at 0.01 μg/g, with a quantitation limit of 0.04 μg/g. The average recovery rate ranged from 89.15% to 95.41%, indicating good reliability of the method. Additionally, the intra-day precision ranged from 4.67% to 6.26%, while the inter-day precision varied between 4.59% and 12.69%, demonstrating favorable reproducibility of the assay. This method is simple, reliable, and highly sensitive, and has been successfully applied to detect HMTD in practical cases. It is suitable for the detection of HMTD in suspected explosives and explosive soil, meeting the needs of actual case investigations.

CLC number: DF794.3 Document code: A Article ID: 1008-3650(2025)05-0515-06

References

【1】
【1】
 
 
Forensic Science and Technology
Pages 515-520

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHOU H, ZHANG L, XU Y, et al. Determination Method of Peroxide Explosive HMTD by GC-MS. Forensic Science and Technology, 2025, 50(5): 515-520. https://doi.org/10.16467/j.1008-3650.2024.0063

0

Views

0

Downloads

0

Crossref

0

Scopus

Received: 07 February 2024
Revised: 18 June 2024
Published: 05 September 2024
© 2025 The Editorial Office of Forensic Science and Technology

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).