AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (14.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Optimization of inlet and outlet configurations for rectangular aquaculture tanks based on model experiments

Chen ZHANG1,2, Huang LIU1( ), Chenglin ZHANG1, Chunjing YAO1,2, Fan ZHANG1,2
Fishery Machinery and Instrument Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200092, China
School of Navigation and Naval Architecture, Dalian Ocean University, Dalian 116023, China
Show Author Information

Abstract

As the core functional unit of aquaculture platforms, aquaculture tank has advantages and disadvantages of its inlet and outlet configurations which have a significant impact on its internal flow field environment. To optimize the hydrodynamic conditions and enhance production efficiency, we established a 1:100 scale physical model based on a 300,000-ton-class rectangular aquaculture tank, employing Particle Image Velocimetry (PIV) for systematic hydrodynamic experimentation. By controlling key parameters including inflow rate and number of inlets, we quantitatively analyzed the evolution characteristics of flow field structures under different inflow conditions. Besides, we investigated the mechanisms by which various outlet structuresaffect vortex field characteristics within the tank. The results demonstrate that: 1) Inflow rate was the primary regulating factor for flow velocity. When the inflow decreased from 1 800 L·h−1 to 900 L·h−1, the high-velocity zone proportion decreased from 33.2% to 8.4%, the low-velocity zone expanded to over 65% of the tank volume, and the average velocity decreased by 52.89%, showing a linear correlation between inflow rate and average velocity. 2) Adjusting the number of inlets was more effective than flow rate modification in improving flow field uniformity. Reducing the number of water inlet decreased the DU50 uniformity coefficient by up to 33.62% across different depths under identical conditions, and up to 39.68% across different conditions at the same cross-section. 3) Variation in the quantity and position of bottom outlets significantly influenced the vortex fieldcharacteristics within the aquaculture tank. When four outlets were installed at the bottom, the vortex effects on the water inside the aquaculture tanks could be effectively avoided.

CLC number: S 953.2 Document code: A Article ID: 2095-0780-(2025)03-0024-12

References

【1】
【1】
 
 
South China Fisheries Science
Pages 24-35

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG C, LIU H, ZHANG C, et al. Optimization of inlet and outlet configurations for rectangular aquaculture tanks based on model experiments. South China Fisheries Science, 2025, 21(3): 24-35. https://doi.org/10.12131/20250094

0

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 24 April 2025
Revised: 13 May 2025
Published: 05 June 2025
© Editorial Office of South China Fisheries Science.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).