AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Dynamic improvement and reliability enhancement of a high speed on/off valve based on pre-excitation soft switching control

Qi ZHONGa,b( ), Weihang ZHOUa,b, Enguang XUa,b, Junxian WANGa,b, Xiaohang SHANa,b, Huayong YANGc
College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China
Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China
State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China

Peer review under responsibility of Editorial Committee of CJA

Show Author Information

Abstract

High Speed on/off Valve (HSV) is an essential component in Aerospace Digital Hydraulic Systems (ADHS), which impose stringent requirements on the dynamic performance and reliability of HSV due to the extreme application environments. However, the faster dynamic leads to increased impact between the spool and valve body, causing severe vibration and wear, which creates a conflict between rapid dynamic and high reliability. To address this problem, a Pre-Excitation Soft Switching Control (PESSC) with both pre-excitation and reverse deceleration functionalities is proposed. The initial current is optimized through pre-excitation to accelerate the opening time, while the application of reverse voltage hastens the decline of electromagnetic force, thereby reducing the spool velocity. The PESSC simultaneously achieves both faster dynamic performance and smaller impact velocity. Moreover, the optimal deceleration voltage parameters are obtained through multi-objective optimization. Experimental results demonstrate that the optimized PESSC shortens the opening time from 2.22 ms to 1.65 ms, reduces the impact velocity by 58.3%, and lowers wear by 55.4%. These findings underline the huge potential of PESSC in enhancing the dynamic performance and reliability of HSVs, offering promising applications in aerospace.

References

【1】
【1】
 
 
Chinese Journal of Aeronautics

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHONG Q, ZHOU W, XU E, et al. Dynamic improvement and reliability enhancement of a high speed on/off valve based on pre-excitation soft switching control. Chinese Journal of Aeronautics, 2026, 39(2). https://doi.org/10.1016/j.cja.2025.103492

926

Views

6

Crossref

7

Web of Science

8

Scopus

0

CSCD

Received: 08 December 2024
Revised: 17 January 2025
Accepted: 03 March 2025
Published: 17 March 2025
© 2025 The Author(s). Chinese Society of Aeronautics and Astronautics.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).