Experimental investigation of instability inception on a transonic compressor under various inlet guide vanes

Tianyu PANa, Jingsai ZHOUa,b, Wenqian WUb, Zhaoqi YANa( ), Qiushi LIa,b,c
Research Institute of Aero-Engine, Beihang University, Beijing 100191, China
School of Energy and Power Engineering, Beihang University, Beijing 100191, China
Key Laboratory of Fluid and Power Machinery, Ministry of Education, Xihua University, Chengdu 610039, China

☆ Special Issue: Excellent Papers of AFC and ADAC.

Peer review under responsibility of Editorial Committee of CJA.

Show Author Information

Abstract

The utilization of Inlet Guide Vane (IGV) plays a key factor in affecting the instability evolution. Existing literature mainly focuses on the effect of IGV on instability inception that occurs in the rotor region. However, with the emergence of compressor instability starting from the stator region, the mechanism of various instability inceptions that occurs in different blade rows due to the change of IGV angles should be further examined. In this study, experiments were focused on three types of instability inceptions observed previously in a 1.5-stage axial flow compressor. To analyze the conversion of stall evolutions, the compressor rotating speed was set to 17160 r/min, at which both the blade loading in the stator hub region and rotor tip region were close to the critical value before final compressor stall. Meanwhile, the dynamic test points with high-response were placed to monitor the pressures both at the stator trailing edges and rotor tips. The results indicate that the variation of reaction determines the region where initial instability occurs. Indeed, negative pre-rotation of the inlet guide vane leads to high-reaction, initiating stall disturbance from the rotor region. Positive pre-rotation results in low-reaction, initiating stall disturbance from the stator region. Furthermore, the type of instability evolution is affected by the radial loading distribution under different IGV angles. Specifically, a spike-type inception occurs at the rotor blade tip with a large angle of attack at the rotor inlet (−2°, −4° and −6°). Meanwhile, the critical total pressure ratio at the rotor tip is 1.40 near stall. As the angle of attack decreases, the stator blade loading reaches its critical boundary, with a value of approximately 1.35. At this moment, if the rotor tip maintains high blade loading similar to the stator hub, the partial surge occurs (0° and +2°); otherwise, the hub instability occurs (+4° and +6°).

References

【1】
【1】
 
 
Chinese Journal of Aeronautics

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
PAN T, ZHOU J, WU W, et al. Experimental investigation of instability inception on a transonic compressor under various inlet guide vanes. Chinese Journal of Aeronautics, 2025, 38(3). https://doi.org/10.1016/j.cja.2024.08.040

833

Views

7

Crossref

6

Web of Science

6

Scopus

0

CSCD

Received: 13 June 2024
Revised: 21 June 2024
Accepted: 08 July 2024
Published: 04 September 2024
© 2024 Chinese Society of Aeronautics and Astronautics

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).