AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Just Accepted

Experimental study on two-phase flow pressure drop and phase separation in a vertical T-junction

Fupeng Wang1,2,3, Rulei Sun1,2,3( ), Shixuan Wang1,2,3, Yaning Sun1,2,3, Sichao Tan1,2,3( ), Ruifeng Tian1,2,3

1 State Key Laboratory of Marine Thermal Energy and Power, Harbin Engineering University, Harbin 150001, China

2 Heilongjiang Provincial Key Laboratory of Nuclear Power System & Equipment, Harbin Engineering University, Harbin 150001, China

3 Key Laboratory of Nuclear Safety and Advanced Nuclear Energy Technology, Ministry of Industry and Information Technology, Harbin Engineering University, Harbin 150001, China

Show Author Information

Abstract

This study experimentally investigates the gas–liquid two-phase flow characteristics in a vertical-main and horizontal-branch T-junction under the condition of complete liquid extraction (liquid separation ratio = 1), which is relevant to passive safety systems. Experiments were conducted in an open-loop circuit with a 28 mm internal diameter using an air–water mixture. Systematic pressure drop measurements coupled with high-speed flow visualization were performed to analyze the pressure drop characteristics and phase separation behavior under various gas and liquid flow rates. The results demonstrate that both the pressure drop and phase separation ratio exhibit nonlinear evolution with increasing gas flow rate, showing a distinct transition at a critical gas flow rate. High-speed imaging analysis confirms that this transition is directly associated with the flow pattern shift from bubbly to slug flow in the main pipe. The liquid flow rate significantly influences the phase separation efficiency by modulating the interfacial mixing intensity. Increasing the liquid flow rate enhances the gas entrainment capability, while the pressure drop evolution displays a two-stage characteristic, transitioning from a two-phase dissipation-dominated regime to a viscosity-dominated regime. Flow visualization further revealed that vortex structures in the junction region serve as a key factor influencing the flow distribution between the main and branch pipes. Based on mechanistic insights and experimental data, a semiempirical correlation was developed to predict the phase separation ratio directly from pressure drop measurements, achieving prediction errors within 15% across the tested range. This model offers a practical tool for the design and monitoring of branching  pipelines in passive safety systems of nuclear reactors. 

References

【1】
【1】
 
 
Experimental and Computational Multiphase Flow

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang F, Sun R, Wang S, et al. Experimental study on two-phase flow pressure drop and phase separation in a vertical T-junction. Experimental and Computational Multiphase Flow, 2026, https://doi.org/10.1007/s42757-026-0290-5

185

Views

9

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 20 October 2025
Revised: 04 February 2026
Accepted: 25 February 2026
Available online: 18 May 2026

© Tsinghua University Press 2026.